Scientists propose distance-based visual miRNA biosensor

Scientists propose distance-based visual miRNA biosensor
Illustration of the sensing principle of the distance-based miRNA assay. Credit: SIBET

Point-of-care testing (POCT) devices show great advantages over conventional diagnostic tests in being accessible to patients and providing timely diagnostic information. The global POCT market has grown remarkably over the past few decades. Distance-based devices are attracting great interest due to their simplicity, affordability, and ease of application.

Researchers at the Suzhou Institute of Biomedical Engineering and Technology (SIBET) of the Chinese Academy of Sciences have proposed a distance-based visual miRNA biosensor based on a DNA hydrogel system. The results of the study, titled "Distance-Based Visual miRNA Biosensor with Strand Displacement Amplification-Mediated DNA Hydrogel Assembly," were published in ACS Materials Letters.

The target miRNA-initiated strand displacement amplification process will produce abundant single-stranded DNA, which are essential probes for the linking of the three-way junction scaffold of the hydrogel.

The phase transition of the solution is confirmed by elastic and electrochemical techniques. A distance-based paper biosensing method is thus set up by establishing the relationship between the seepage flow distance along the strip and the initial miRNA concentration.

  • Scientists propose distance-based visual miRNA biosensor
    Principle of the elasticity instrument and the optimization by amplitude comparison. Credit: SIBET
  • Scientists propose distance-based visual miRNA biosensor
    A. Photograph of filter strips after the reactions with different amounts of miRNA; B. Seepage flow distances of DNA hydrogel induced by miRNA; C. Linear relationship; D. Flow distances of DNA hydrogel induced by let-7a and the family members; E. Comparison of the flow distances; F. Concentrations of miRNA in control and patient samples. Credit: SIBET

Due to the strand displacement amplification, the biosensor is not only simple but also highly sensitive with a detection limit down to 1 fM.

Since the three-dimensional DNA provides abundant binding sites, the detection range is quite wide, according to the researchers.

The is shown to be highly selective, and the results of human serum analysis are consistent with standard quantitative reverse transcription-PCR.

"This approach has the advantages of convenient operation and low cost, which meets the requirements of point-of-care testing," said Miao Peng, lead author of the study. "It is promising as a convenient tool for miRNA-related biological studies and ."

More information: Chengyu Yan et al, Distance-Based Visual miRNA Biosensor with Strand Displacement Amplification-Mediated DNA Hydrogel Assembly, ACS Materials Letters (2024). DOI: 10.1021/acsmaterialslett.4c00650

Citation: Scientists propose distance-based visual miRNA biosensor (2024, June 13) retrieved 18 June 2024 from https://phys.org/news/2024-06-scientists-distance-based-visual-mirna.html
This document is subject to copyright. Apart from any fair dealing for the purpose of private study or research, no part may be reproduced without the written permission. The content is provided for information purposes only.

Explore further

MXene-enhanced plasmonic sensing developed for ultrasensitive label-free miRNA detection