This article has been reviewed according to Science X's editorial process and policies. Editors have highlighted the following attributes while ensuring the content's credibility:

fact-checked

peer-reviewed publication

trusted source

proofread

Tissue-integrated sensitive glucose nanosenor uses inactive glucose oxidase enzyme for continuous monitoring

Tissue-integrated sensitive glucose nanosenor using inactive glucose oxidase enzyme
Credit: Angewandte Chemie International Edition (2023). DOI: 10.1002/anie.202311476

Monitoring glucose levels is one of the key elements in health monitoring. A research team from the University of California, Berkeley, has now developed a battery-independent fluorescent nanosensor based on single-wall carbon nanotubes and an inactive form of the enzyme glucose oxidase (GOx).

Because the enzyme is not in its active form, the analyte is not consumed during the measurement, and continuous, reversible, and non-invasive bioimaging of in and tissues is possible, the team reports in the journal Angewandte Chemie International Edition.

Blood glucose levels are typically measured using GOx-based electrochemical sensors. However, these sensors produce toxic hydrogen peroxide as a byproduct and, furthermore, require bulky electrical circuits and batteries, making it difficult to prepare implantable devices for continuous measurement.

Tiny SWCNTs, on the other hand, can be integrated into tissues and provide bioimaging information: when excited by light, SWCNTs produce a near-infrared fluorescence signal that travels through tissue and can be easily recorded using non-invasive bioimaging techniques.

Unfortunately, making GOx-based SWCNT nanosensors is difficult because the most effective technology for loading molecules onto SWCNTs—sonication—essentially inactivates the GOx molecules.

Now, Markita P. Landry and her research team at the University of California, Berkeley have disproved the assumption that GOx-based sensors require active GOx for successful glucose sensing. Using sonication, they prepared GOx-loaded SWCNT sensors that reliably, selectively, and sensitively detected glucose, as demonstrated for glucose measurements in serum, plasma, and mouse brain slices.

The researchers explained this surprising finding by the ability of the inactive GOx enzyme to bind glucose without converting it. Binding alone was sufficient to modulate the fluorescence signal. To be completely independent of GOx activity, the researchers also constructed a GOx enzyme that even lacked the reactive group for glucose conversion. The resulting apo-GOx-SWCNT sensor detected glucose in body fluids and mouse brain slices as reliably as the original conjugate of SWCNT and natural GOx.

The researchers point out that the use of inactive GOx molecules has major advantages. For example, the manufacturing process of the GOx-SWCNT nanosensors can be simplified by using sonication as an effective preparation step. In addition, as the analyte is not consumed by the reaction, no toxic byproducts are produced, and the measurements are intrinsically reversible, allowing for non-invasive continuous monitoring in tissue fluids.

More information: Shoichi Nishitani et al, Engineered Glucose Oxidase‐Carbon Nanotube Conjugates for Tissue‐Translatable Glucose Nanosensors, Angewandte Chemie International Edition (2023). DOI: 10.1002/anie.202311476

Provided by Wiley

Citation: Tissue-integrated sensitive glucose nanosenor uses inactive glucose oxidase enzyme for continuous monitoring (2024, January 2) retrieved 27 April 2024 from https://phys.org/news/2024-01-tissue-integrated-sensitive-glucose-nanosenor-inactive.html
This document is subject to copyright. Apart from any fair dealing for the purpose of private study or research, no part may be reproduced without the written permission. The content is provided for information purposes only.

Explore further

Self-driven disposable sensor for easy measurement of blood glucose levels at home

39 shares

Feedback to editors