Unwanted side effect becomes advantage in photoacoustic imaging

Jan 15, 2014 by Beth Miller
Unwanted side effect becomes advantage in photoacoustic imaging
The images above show melanoma cells (top) and rose petal epidermal cells (bottom) using conventional photoacoustic microscopy (PAM) (left) and photo imprint photoacoustic microscopy. The resolution is considerably sharper in the photo imprint PAM image.

(Phys.org) —Biomedical engineer Lihong Wang, PhD, and researchers in his lab work with lasers used in photoacoustic imaging for early-cancer detection and a close look at biological tissue. But sometimes there are limitations to what they can do, and as engineers, they work to find a way around those limitations.

Wang, the Gene K. Beare Distinguished Professor of Biomedical Engineering in the School of Engineering & Applied Science at Washington University in St. Louis, and Junjie Yao, PhD, a postdoctoral research associate in Wang's lab, found a unique and novel way to use an otherwise unwanted side effect of the lasers they use—the photo bleaching effect—to their advantage.

The results were published online Jan. 10 in Physical Review Letters.

The researchers use an optical microscopy method called photoacoustic microscopy to take an intensely close look at tissues. The is a mere 200 nanometers wide. However, the center of the laser beam is so strong that it bleaches the center of the tissue sample. When researchers pulse the laser beam on the tissue, the molecules no longer give signals packed with information.

A second pulse probes the molecules that are left in the boundary of the sample. In this pulse, the molecules in the center of the sample provide a weaker signal because they are already bleached.

"Previously when a molecule was prone to bleaching, researchers didn't want to use it because they couldn't get enough information from it," Yao says. "Now for us, that is good news."

Wang and Yao subtracted the boundary area of the sample, leaving only the center—or what they call a photo imprint—now down to 80 nanometers wide, providing a very high, or super-resolution, picture. A smaller diameter of the center provides a better resolution in the image.

"In the end, we effectively shrink the detection spot to a smaller region," Yao says. "Eighty nanometers allows us to see a lot of subcellular features, such as mitochondria or cell nuclei."

After each area of the sample is scanned, the researchers create an image. With previous photoacoustic microscopy imaging, the microspheres on the image were blurry. However, with the new photo-imprint photoacoustic microscopy, the resulting image is clear and sharp.

"When we improve the resolution, we can see the cell structure with much more detail," Yao says. "For biologists, these are much more informative images."

Those working in imaging could apply this method to their own research, Yao says.

Explore further: Medical imaging breakthrough may lead to early cancer detection

More information: Yao J, Wang L, Li C, Zhang C, Wang LV. Photo-imprint Photoacoustic Microscopy for Three-dimensional Label-free Sub-diffraction Imaging. Physical Review Letters. Published online Jan. 10, 2014. Vol. 112, 014302 (2014).

Related Stories

'Super-resolution' microscope possible for nanostructures

Apr 29, 2013

(Phys.org) —Researchers have found a way to see synthetic nanostructures and molecules using a new type of super-resolution optical microscopy that does not require fluorescent dyes, representing a practical ...

Recommended for you

Finding faster-than-light particles by weighing them

Dec 26, 2014

In a new paper accepted by the journal Astroparticle Physics, Robert Ehrlich, a recently retired physicist from George Mason University, claims that the neutrino is very likely a tachyon or faster-than-light par ...

Controlling core switching in Pac-man disks

Dec 24, 2014

Magnetic vortices in thin films can encode information in the perpendicular magnetization pointing up or down relative to the vortex core. These binary states could be useful for non-volatile data storage ...

Atoms queue up for quantum computer networks

Dec 24, 2014

In order to develop future quantum computer networks, it is necessary to hold a known number of atoms and read them without them disappearing. To do this, researchers from the Niels Bohr Institute have developed ...

New video supports radiation dosimetry audits

Dec 23, 2014

The National Physical Laboratory (NPL), working with the National Radiotherapy Trials Quality Assurance Group, has produced a video guide to support physicists participating in radiation dosimetry audits.

Acoustic tweezers manipulate cell-to-cell contact

Dec 22, 2014

Sound waves can precisely position groups of cells for study without the danger of changing or damaging the cells, according to a team of Penn State researchers who are using surface acoustic waves to manipulate ...

User comments : 0

Please sign in to add a comment. Registration is free, and takes less than a minute. Read more

Click here to reset your password.
Sign in to get notified via email when new comments are made.