Biomedical imaging at one-thousandth the cost

November 23, 2015 by Larry Hardesty
Biomedical imaging at one-thousandth the cost
MIT researchers have developed a new biomedical imaging system that harnesses an off-the-shelf depth sensor such as Microsoft’s Kinect. The coloration of these images depicts the phase information contained in six of the 50 light frequencies the system analyzes.

MIT researchers have developed a biomedical imaging system that could ultimately replace a $100,000 piece of a lab equipment with components that cost just hundreds of dollars.

The system uses a technique called fluorescence lifetime imaging, which has applications in DNA sequencing and cancer diagnosis, among other things. So the new work could have implications for both biological research and clinical practice.

"The theme of our work is to take the electronic and optical precision of this big expensive microscope and replace it with sophistication in mathematical modeling," says Ayush Bhandari, a graduate student at the MIT Media Lab and one of the system's developers. "We show that you can use something in consumer imaging, like the Microsoft Kinect, to do bioimaging in much the same way that the microscope is doing."

The MIT researchers reported the new work in the Nov. 20 issue of the journal Optica. Bhandari is the first author on the paper, and he's joined by associate professor of media arts and sciences Ramesh Raskar and Christopher Barsi, a former research scientist in Raskar's group who now teaches physics at the Commonwealth School in Boston.

Fluorescence lifetime imaging, as its name implies, depends on fluorescence, or the tendency of materials known as fluorophores to absorb light and then re-emit it a short time later. For a given fluorophore, interactions with other chemicals will shorten the interval between the absorption and emission of light in a predictable way. Measuring that interval—the "lifetime" of the fluorescence—in a biological sample treated with a fluorescent dye can reveal information about the sample's chemical composition.

In traditional fluorescence lifetime imaging, the imaging system emits a burst of light, much of which is absorbed by the sample, and then measures how long it takes for returning light particles, or photons, to strike an array of detectors. To make the measurement as precise as possible, the light bursts are extremely short.

The fluorescence lifetimes pertinent to are in the nanosecond range. So traditional fluorescence lifetime imaging uses light bursts that last just picoseconds, or thousandths of nanoseconds.

Blunt instrument

Off-the-shelf depth sensors like the Kinect, however, use light bursts that last tens of nanoseconds. That's fine for their intended purpose: gauging objects' depth by measuring the time it takes light to reflect off of them and return to the sensor. But it would appear to be too coarse-grained for fluorescence lifetime imaging.

The Media Lab researchers, however, extract additional information from the by subjecting it to a Fourier transform. The Fourier transform is a technique for breaking signals—optical, electrical, or acoustical—into their constituent frequencies. A given signal, no matter how irregular, can be represented as the weighted sum of signals at many different frequencies, each of them perfectly regular.

The Media Lab researchers represent the optical signal returning from the sample as the sum of 50 different frequencies. Some of those frequencies are higher than that of the signal itself, which is how they are able to recover information about fluorescence lifetimes shorter than the duration of the emitted burst of light.

For each of those 50 frequencies, the researchers measure the difference in phase between the emitted signal and the returning signal. If an electromagnetic wave can be thought of as a regular up-and-down squiggle, phase is the degree of alignment between the troughs and crests of one wave and those of another. In , phase shift also carries information about the fluorescence lifetime.

Not all of the light that strikes the biological sample is absorbed; some of it is reflected back. The MIT researchers' system takes the measurements of incoming light and fits them to a mathematical model of the overlapping intensity profiles of both reflected and re-emitted light.

Once it's deduced the intensity profile of the reflected light, it can calculate the distance between the emitter and the sample. So unlike conventional fluorescence lifetime imaging, the researchers' approach doesn't require distance calibration.

Sample size

According to Bhandari, some of his colleagues were skeptical that the returning light signal contained enough information to produce accurate models of the intensity profiles. "They were not convinced that the precision of Kinect-like sensors is enough," he says. "But lifetime and distance are two numbers. If you have two numbers, then 50 measurements is a lot. The desired information is two points, but the measurement is 50 points, so you have a ratio of one to 25. It's enough to give you the intuition that it should be workable."

The depth sensors that the researchers used in their experiments—the Kinect and others—had arrays of roughly 20,000 light detectors each, and the most accurate results came when the detector was 2.5 meters away from the biological sample. That setup doesn't afford the image resolution that existing fluorescence lifetime imaging microscopes do. But while denser arrays of detectors and optics that better control the emission and gathering of light would inflate the cost of the researchers' system beyond the $100 that a Kinect costs, it still shouldn't be nearly as expensive as current fluorescence lifetime imaging systems.

"If I had one of these devices, what I would do is just go looking around the world at stuff," says Adam Cohen, a professor of chemistry and chemical biology and of physics at Harvard University. "There might be all sorts of interesting things. It's a new modality for looking around the world. It's just like, humans can't see polarization in the —we only see color—and there's all this structure that insects can see because they can see polarization that we're just blind to. To my knowledge, there's no living organism that can see excited-state lifetime, and so there's this contrast modality that has not been explored by life that nonetheless might be very interesting. So I'd look at it."

Explore further: New imaging technology helping detect oral cancer more accurately

More information: Ayush Bhandari et al. Blind and reference-free fluorescence lifetime estimation via consumer time-of-flight sensors, Optica (2015). DOI: 10.1364/OPTICA.2.000965

Related Stories

Brightness-equalized quantum dots improve biological imaging

October 5, 2015

Researchers at the University of Illinois at Urbana-Champaign have introduced a new class of light-emitting quantum dots (QDs) with tunable and equalized fluorescence brightness across a broad range of colors. This results ...

Researchers open 'Golden Window' in deep brain imaging

November 11, 2015

The neuroscience community is saluting the creation of a "Golden Window" for deep brain imaging by researchers at The City College of New York led by biomedical engineer Lingyan Shi. This is a first for brain imaging, said ...

Recommended for you

Quantum research race lights up the world

September 30, 2016

The race towards quantum computing is heating up. Faster, brighter, more exacting – these are all terms that could be applied as much to the actual science as to the research effort going on in labs around the globe.

First spectroscopic investigation of element nobelium

September 30, 2016

The analysis of atomic spectra is of fundamental importance for our understanding of atomic structures. Until now, researchers were unable to examine heavy elements with optical spectroscopy because these elements do not ...

4 comments

Adjust slider to filter visible comments by rank

Display comments: newest first

TopCat22
1 / 5 (2) Nov 23, 2015
...and tri-quarters for all.

How long will the Medical Privateers hold this technology back?
antialias_physorg
5 / 5 (4) Nov 23, 2015
How long will the Medical Privateers hold this technology back?

Not at all, since they already published it. It's out in the open (read: once published in a scientific journal you can't patent it anymore).
Anyone can buy a Kinect or similar, and Fourier transforms are easily performed with free software packages. With minmal effort you can build this thing at home.

As they note: it doesn't afford the resolution of the high-end machines currently on the market. And for medical laboratories in the developed world 100k$ for a machine isn't exactly a lot of money. So the tradeoff between cost and resolution is likely not an issue there
But for third world countries this is a real alternative.
Captain Stumpy
4 / 5 (4) Nov 23, 2015
But for third world countries this is a real alternative.
@AA_P
I was going to ask you about this ... glad you chimed in

it can also be a boon in lower income & very rural areas in developed countries or to drop costs in lab testing by having a multi-stage approach (test cheap first... go high-res only if the need arises)

antialias_physorg
5 / 5 (2) Nov 23, 2015
it can also be a boon in lower income & very rural areas in developed countries

The way I see it most developed countries have a good postal/medical delivery system. Usually these kinds of tests are done at regional centers.
It'd be rather unusual that a cancer or DNA test is so time critical that it has to be done immediatley and on the spot, so there's probably not much advantage in having this if better facilities are just a few hours' drive away.
In medicine there's also little to be gained from a low quality test if better tests are available - unless that test never gives you a false negative. Otherwise you'd have to have it checked with the expensive test in any case - so you'd just be double spending. Especially cancer tests are tricky that way.
(A cheap test you rely on which does give false negatives would lower medical care quality)

Please sign in to add a comment. Registration is free, and takes less than a minute. Read more

Click here to reset your password.
Sign in to get notified via email when new comments are made.