New bacteria resistant materials discovered

Aug 12, 2012
New bacteria resistant materials discovered

(Phys.org) -- Using state-of-the-art technology scientists at The University of Nottingham have discovered a new class of polymers that are resistant to bacterial attachment. These new materials could lead to a significant reduction in hospital infections and medical device failures.

Medical device associated infections can lead to systemic infections or device failure, costing the NHS 1bn a year. Affecting many commonly used devices including urinary and venous catheters — bacteria form communities known as biofilms. This 'strength in numbers approach' protects them against the bodies’ natural defences and antibiotics.

Experts in the Schools of Pharmacy and Molecular Medical Sciences, have shown that when the are applied to the surface of medical devices they repel bacteria and prevent them forming biofilms.

The research was led by Professor Morgan Alexander, and Professor Martyn Davies in the School of Pharmacy and Professor Paul Williams in the School of Molecular Medical Sciences. The results have been published today in Nature Biotechnology.

This video is not supported by your browser at this time.

The novel materials had to be found using a new technique

Researchers believed there were new materials that could resist bacteria better but they had to find them. This meant screening thousands of different chemistries and testing their reaction to bacteria — a challenge which was beyond conventional materials development or any of our current understanding of the interaction of micro-organisms with surfaces.

The discovery has been made with the help of experts from the Massachusetts Institute of Technology (MIT) — who initially developed the process by which thousands of unique polymers can now be screened simultaneously.

Professor Alexander said: “This is a major scientific breakthrough — we have discovered a new group of structurally related materials that dramatically reduce the attachment of pathogenic bacteria (Pseudomonas aeruginosa, Staphylococcus aureus and Escherichia coli). We could not have found these materials using the current understanding of bacteria-surface interactions. The technology developed with the help of MIT means that hundreds of materials could be screened simultaneously to reveal new structure-property relationships. In total thousands of materials were investigated using this high throughput materials discovery approach leading to the identification of novel materials resisting bacterial attachment. This could not have been achieved using conventional techniques.”

These new materials prevent infection by stopping biofilm formation at the earliest possible stage — when the bacteria first attempt to attach themselves to the device. In the laboratory experts were able to reduce the numbers of bacteria by up to 96.7per cent — compared with a commercially available silver containing catheter — and were effective at resisting bacterial attachment in a mouse implant infection model. By preventing bacterial attachment the body’s own immune system can kill the bacteria before they have time to generate biofilms.

Ted Bianco, Director of Technology Transfer at the Wellcome Trust, said: “Infections caused by microbial biofilms binding to the surface of implants often cannot be treated with conventional antibiotics. This makes them a significant challenge in patient care, particularly for those with inserted medical devices like catheters, heart valves and prosthetic joints. The discovery of these new polymers is a great example of how advances in materials science are being exploited in our efforts to improve the performance of critical medical components. Just as materials science gave us the non-stick saucepan, so we look forward to the day of the ‘non-stick’ medical device.”

Bacterial attachment and subsequent biofilm formation are key challenges to the performance of . This is early stage research but the initial results are very promising. The next stage of this research will be to develop the manufacture of these coatings to enable the performance of these to be assessed clinically and the inventors are in early stage discussions with a number of device companies.

Explore further: Automating the selection process for a genome assembler

Related Stories

Improved antibiotic coatings

Oct 19, 2010

Bacteria have a natural ability to attach themselves to surfaces, both natural and synthetic. Once attached, they often work cooperatively to form biofilms, thin layers of bacterial colonies that can coat the surface of a ...

Antimicrobial catheters could save NHS millions

Mar 27, 2012

A new catheter coating that reduces bacterial attachment to its surface is being developed by scientists who are reporting their work at the Society for General Microbiology's Spring Conference in Dublin this ...

Recommended for you

Studies steadily advance cellulosic ethanol prospects

22 hours ago

At the Agricultural Research Service's Bioenergy Research Unit in Peoria, Illinois, field work and bench investigations keep ARS scientists on the scientific front lines of converting biomass into cellulosic ...

User comments : 2

Adjust slider to filter visible comments by rank

Display comments: newest first

h20dr
5 / 5 (1) Aug 12, 2012
Biofilm suppression is the new frontier in potable drinking water systems so this is welcome news indeed for that industry too. I am sure there are innumerable applications we have not even thought of yet and for technologies yet to be invented.
antialias_physorg
not rated yet Aug 13, 2012
Would be interesting to pit this against this material:
http://phys.org/n...ces.html
from a physorg article two weeks ago.