Report on Texas fire urges firefighters to consider wind effects

Feb 08, 2012 By Michael E. Newman

(PhysOrg.com) -- Wind conditions at a fire scene can make a critical difference on the behavior of the blaze and the safety of firefighters, even indoors, according to a new report by the National Institute of Standards and Technology. The findings confirm earlier NIST research, but they take on a particular immediacy because they are based on detailed computer models of a tragic 2009 residential fire in Houston, Texas, that claimed the lives of two firefighters.

The NIST modeling was done at the request of the Houston Department (HFD) and the ’s National Institute for Occupational Safety and Health (NIOSH), both of which wanted expert insight into the fire dynamics (behavior) that killed a 29-year veteran captain and a probationary firefighter.

Two NIST fire experts traveled to Houston shortly after the April 12, 2009, fire in a one-story ranch-style home located on the east side of the city. They examined the site and collected data about the behavior of the fire and the factors impacting that behavior—in particular, the wind at the time—in order to unravel the events that led to the deaths of the two men.

This was accomplished by creating sophisticated computer models of the fire and then visualizing them using two popular NIST software tools: the Fire Dynamics Simulator (FDS), which numerically characterizes the movement of smoke and hot gases caused by fire, wind and ventilation systems; and Smokeview, which displays the FDS calculation results as animations. The simulations portrayed two different scenarios of the Houston fire. The first demonstrated the actual conditions that experienced that day, including the contributing role of wind, while the second was intended to show how the fire may have behaved in the absence of wind. The wind-included scenario indicated that the fire followed a wind-driven flow path between the den and the front door after the failure of a large span of windows in the den. Floor-to-ceiling temperatures rapidly increased—in some areas, in excess of 260 degrees Celsius (500 degrees Fahrenheit)—in this flow path where multiple crews of firefighters were working. In the NIST simulation that excluded wind, the flow path was not created, and the temperatures and conditions where the firefighters were working were significantly less hazardous.

The authors of the NIST report, Adam Barowy and Daniel Madrzykowski, stated that “the ‘wind’ and ‘no wind’ simulations clearly demonstrate how wind conditions can rapidly change the thermal environment from tenable (survivable) to untenable for firefighters working in a single-story residential structure fire.” They add that the results from the Houston fire simulations are in agreement with those NIST has done in collaboration with the Fire Department of New York City and the Chicago Fire Department for wind-driven fires in high-rise structures. This, the authors said, stresses the importance of including for all structural fire scene operations—both before and during firefighting—and adjusting tactics according to changing situations, especially regarding interior operations, to enhance the safety, and maximize the effectiveness, of firefighters.

Explore further: Australia, Malaysia, Indonesia to trial new jet tracking system

More information: The NIST report that describes the details of the computer models and what was learned from them, Simulation of the Dynamics of a Wind-Driven Fire in a Ranch-Style House—Texas (NIST Technical Note 1729), is available online at www.nist.gov/customcf/get_pdf.cfm?pub_id=909779 .

add to favorites email to friend print save as pdf

Related Stories

NIST residential fire study education kit now available

Sep 29, 2010

Researchers from the National Institute of Standards and Technology (NIST) and the International Association of Fire Fighters have prepared an educational resource for fire chiefs, firefighters, and public ...

'Smart' Buildings to Guide Future First Responders

Nov 03, 2005

NIST researchers are studying how "intelligent" building systems can be used by firefighters, police and other first responders to accurately assess emergency conditions in real-time. One of the biggest problems faced by ...

NIST Test Fans the Flames for High-Rise Fire Safety

Nov 22, 2006

Reseearchers from NIST, the Chicago Fire Department and the Chicago Housing Authority recently set controlled fires in an abandoned Chicago apartment building to test a new fire-fighting technique -- using ...

Recommended for you

Phone firms and the quest for the 5G Holy Grail

43 minutes ago

Lightning-quick downloads, driverless cars and remote surgery: telecom firms are racing to develop a new generation of "5G" mobile networks that could start to change the world in five years.

Fujitsu shows iris recognition system that unlocks phones

53 minutes ago

In the bid to come up with authentication solutions beyond passwords, fingerprint authentication from Qualcomm is making news, and so is Fujitsu's iris recognition, yet another potential authentication tech ...

Supreme Court allows challenge to Colorado Internet tax law

2 hours ago

A unanimous Supreme Court ruled Tuesday that federal courts can hear a dispute over Colorado's Internet tax law. One justice suggested it was time to reconsider the ban on state collection of sales taxes from companies outside ...

New incubator network to help clean-energy entrepreneurs

3 hours ago

The Energy Department's National Renewable Energy Laboratory (NREL) and the Electric Power Research Institute (EPRI) have launched the Clean Energy Incubator Network. The program, funded by the Energy Department, aims to ...

User comments : 0

Please sign in to add a comment. Registration is free, and takes less than a minute. Read more

Click here to reset your password.
Sign in to get notified via email when new comments are made.