This article has been reviewed according to Science X's editorial process and policies. Editors have highlighted the following attributes while ensuring the content's credibility:

fact-checked

peer-reviewed publication

trusted source

proofread

A modern digital light processing technology to 3D print microfluidic chips

A modern digital light processing technology to 3-D print microfluidic chips
Scheme showing the design principle of the DZC-VPP fabrication process. a) Schematic image showing the setup of the DZC-VPP apparatus. b) CAD design of batch printing. c) Photograph of batch printing productions. The scale bar is 1 cm. d) Orthographic views of the channel structure (x-y axis) and the drop-maker microfluidic chip design with the bottom layer (height: b μm), channel layer (height: h μm, width: h μm), connection layer (height: c μm), and roof layer (height: a μm). e) The process design of DZC-VPP. Fabrication of the bottom layers (i) and channel layers (ii) using the conventional equal-step DLP process. iii. Fabrication of the first wall-roof connection layer, in which the UV dose is equal to the bottom layer; iv. Fabrication of the first channel-roof connection layer using a critical dose; v. Fabrication of the subsequent wall-roof connection layer; vi. Fabrication of the subsequent channel-roof connection layer; vii. Fabrication of the roof layers using the conventional DLP process Credit: Microsystems & Nanoengineering (2023). DOI: 10.1038/s41378-023-00542-y

Conventional manufacturing methods such as soft lithography and hot embossing processes can be used to bioengineer microfluidic chips, albeit with limitations, including difficulty in preparing multilayered structures, cost- and labor-consuming fabrication processes as well as low productivity.

Materials scientists have introduced digital light processing as a cost-effective microfabrication approach to 3D print microfluidic chips, although the fabrication resolution of these microchannels are limited to a scale of sub-100 microns.

In a new report published in Microsystems and Nanoengineering, Zhuming Luo and a scientific team in , and chemical engineering in China developed an innovative digital light processing method.

They proposed a modified mathematical model to predict UV irradiance for resin photopolymerization and guided the fabrication of microchannels with increased resolution. The advanced microfabricating method can facilitate major developments in precise and scalable microchannel formation as a significant next step for widespread applications in microfluidics-based strategies in biomedicine.

Microfluidic chips

The microfluidics chips offer a powerful tool to miniaturize applications in 3D cell culture for drug screening and testing applications and organ-on-a- assays. Conventional methods to develop microfluidic chips include soft lithography and hot capillary fabrication with a complicated engineering process, low productivity and high cost.

3D bioprinting has attracted increasing attention to innovatively design and manufacture customized structures at the microscale. Materials scientists have used digital light processing for layer-by-layer vat photopolymerization to microfabricate with resolutions up to tens of microns with rapid processing speed and ease of function.

In this work, Luo and colleagues developed a new digital light processing method for high-resolution and scale-up fabrication of microfluidic devices by dosing and zoning vat polymerization. The team fine-tuned the printing parameters and other parameters to precisely tailor the photopolymerization of neighboring resin layers and avoid channel blocking due to excessive UV exposure.

When compared to conventional methods, the process allowed the one-batch development of up to 16 microfluidic chips. The current method can facilitate major advances in precise and scalable microchannel development as a significant step forward of microfluidics-based devices in biomedicine.

Using a mathematical model to predict the characteristic parameters of resin

The team regulated the UV irradiation dosage by applying stepwise UV to polymerize the resin layer-by-layer by using a mathematical model. Upon UV irradiation for a specific exposure time, the scientists polymerized a specific depth of the resin solution. Then, using the mathematical model, they determined a comprehensive method to calculate the threshold of resin polymerization. The printing path incorporated in the work precisely divided the microchannel into the bottom layer, channel layer and roof layer.

Design rationale and experimental setup for microchannel development

Based on the outcomes, the researchers proposed a modified version of digital light process (DLP) printing strategy to fabricate substantially small microchannels through dosing- and zoning-regulated vat photopolymerization (abbreviated DZC-VPP). This process divided the microchannels into several layers. The capacity to regulate the zones for each projection step allowed the precise regulation of local resin polymerization, the scientists successfully printed the channels with significantly higher resolution.

The team studied the printing quality of the new approach by comparing it with the conventional method. While the conventional method led to poor fidelity of channels due to the accumulation of excessive UV exposure, the new method contrastingly offered microchannels with significantly improved printing fidelity to allow the development of smoother internal surfaces within the microchannels with significant impact on liquid manipulation. The DZC-VPP method is additionally highly scalable and cost-effective.

A modern digital light processing technology to 3-D print microfluidic chips
Experimental data of DZC-VPP chips for the customized production of microdroplets and microgels. a) Photograph shows the volume of a single DZC-VPP chip in comparison to the coin, and the microscope images show flow patterns generated in the microfluidic device at different channel sizes of 20 μm (i), 100 μm (ii), and 300 μm (iii). Scale bars are 1 cm in photographs and 100 μm in microscope images. b) Representative microscope images of microdroplets generated by DZC-VPP chips with channel sizes of 20 μm (i), 100 μm (ii), and 300 μm (iii). Scale bars are 300 μm. c) Representative confocal microscopic images of microgels generated by DZC-VPP chips with channel sizes of 20 μm (i), 100 μm (ii), and 300 μm (iii). Scale bars are 300 μm. d) Size distribution of microdroplets and microgels generated by DZC-VPP chips (five chips for each sample) with channel sizes of 20 μm (i), 100 μm (ii), and 300 μm (iii). Credit: Microsystems & Nanoengineering (2023). DOI: 10.1038/s41378-023-00542-y

Mechanical stability of the developed materials

Luo and colleagues next investigated the mechanical stability of the microfluidic devices engineered with the new DZC-VPP method and again compared it with the conventional process. While mechanical stability is crucial for the microfluidic chips to tolerate high liquid pressure, the two materials demonstrated similar stress-strain curves.

The DZC-VPP fabricated chip showed significantly higher fracture stress and strain when compared to the DLP chip, indicating that the new strategy improved both printing resolution and mechanical stability of the engineered microfluidic chips.

Generating droplets and microgels and encapsulating cells with microgels

To accomplish microfluidic generation of droplets, the scientists used pure water as the aqueous phase and an oil-glycol emulsion to create monodisperse aqueous droplets. The team encapsulated the cells with microgels in the fabricated chips by using the alginate system. To prevent cytotoxicity in the instrument, the researchers tested the biocompatibility of the chips using cell-laden microgels.

Both HeLa cells and rat mesenchymal cells used in the study retained cell viability after encapsulation to gradually proliferate into cell clusters, indicating the biofriendly nature of the DZC-VPP engineered microfluidic device. The method is also best suited for other cell-related applications including the development of organ-on-a-chip instruments.

When compared to the conventional digital light printing process, the newer DC-VPP method can regulate the UV penetration depth for resin photopolymerization. The outcomes highlighted the reliability of the new process for high-resolution printing to fabricate 3D printed .

Outlook

In this way, Zhuming Luo and the research team developed a new dosing and zoning regulated vat photopolymerization (abbreviated DZC-VPP) method to 3D print microchannels with improved resolution and mechanical stability. The team accomplished this by proposing a mathematical model to predict the accumulated UV irradiance for resin polymerization as a guide to design and print the microchannels.

Using the approach, the team printed a microchannel with conventional soft lithography or hot embossing to generate high throughput monodisperse droplets and cell-laden microgels. This highly efficient method of microfabrication represents a key step for high resolution, scaled up fabrication of microfluidic devices for widespread applications.

More information: Zhiming Luo et al, Digital light processing 3D printing for microfluidic chips with enhanced resolution via dosing- and zoning-controlled vat photopolymerization, Microsystems & Nanoengineering (2023). DOI: 10.1038/s41378-023-00542-y

Fei Shao et al, Microfluidic Encapsulation of Single Cells by Alginate Microgels Using a Trigger-Gellified Strategy, Frontiers in Bioengineering and Biotechnology (2020). DOI: 10.3389/fbioe.2020.583065

Journal information: Microsystems and Nanoengineering

© 2023 Science X Network

Citation: A modern digital light processing technology to 3D print microfluidic chips (2023, September 18) retrieved 28 April 2024 from https://phys.org/news/2023-09-modern-digital-technology-3d-microfluidic.html
This document is subject to copyright. Apart from any fair dealing for the purpose of private study or research, no part may be reproduced without the written permission. The content is provided for information purposes only.

Explore further

New 3D printing technique is a game changer for medical testing devices

68 shares

Feedback to editors