Nanotextured implant materials: blending in, not fighting back

Apr 09, 2007
Nanotextured implant materials: blending in, not fighting back
The faster endothelial cells (green) form a single smooth layer, the less chance exposed metal will provoke an immune response. Samples examined after 1, 3 and 5 days (left to right) show better coverage on nanotextured titanium (bottom row) than on conventional microstructured titanium. Credit: Image: Thomas Webster

Biomedical engineers are constantly coming up with ways to repair the human body, replacing defective and worn out parts with plastic, titanium, and ceramic substitutes – but the body does not always accept such substitutes seamlessly. Engineers from Brown and Purdue universities have found that simply changing the surface texture of implants can dramatically change the way cells colonize a wide variety of materials.

Two recent experiments have focused on the materials used in stents – those springy little cylinders that hold open once-clogged arteries – and artificial blood vessels. Currently only about 30 percent of small diameter blood vessel grafts (less than 6 mm diameter) last more than five years, and up to 20 percent of stents need to be replaced because the artery walls thicken in and around them in a process known as restenosis. Drug-coated stents were introduced years ago as one way to combat this problem, but concerns have surfaced recently about increased clotting.

Instead of using chemistry to fight the body's response to such foreign materials, Thomas Webster, an associate professor of engineering, and Karen Haberstroh, an assistant professor of engineering, thought maybe they could use physical structure to allow the foreign materials to blend in better. "What we're trying to do is fundamentally different," says Webster. "We're trying to find materials that the body accepts, rather than develop drugs or develop materials that will kill a cell – no matter if it kills a bad cell or a good cell. We're trying to find materials that accept good cells, as opposed to killing off bad cells."

Normal healthy blood vessels have a thin lining of specialized cells called the endothelium, surrounded by a thicker layer of smooth muscle cells that make up the arterial wall. The proteins collagen and elastin make up much of this lining and create a texture of fine nanoscale bumps on the inside of the blood vessel. This contrasts strongly with most of the materials used in implants, which have microscale texture, but are nearly smooth at the nanoscale.

When the researchers changed the surface texture of implant materials to better match the natural texture of the endothelium, they found that endothelial cells quickly colonized the foreign surfaces, effectively camouflaging them and preventing smooth muscle cells from overgrowing the implants. Once the endothelial cells form a single, solid layer, they stop piling on and switch to producing the proteins collagen and elastin.

In one experiment, published with Purdue University graduate student Saba Choudhary in the journal Tissue Engineering, Webster and Haberstroh pressed together titanium particles that were less than 1 micron in size to create titanium with nanoscale surface texture. When they compared samples of the nanostructured material to conventional titanium in mixed cell culture, they found that the nanoscale surface features encouraged endothelial cells to colonize the material and spread much faster than smooth muscle cells. Where endothelial cells established themselves, they formed a single thin layer that inhibited overgrowth of the smooth muscle cells that tends to narrow stented arteries.

In another experiment, published in the Journal of Biomedical Materials Research with Purdue graduate student Derick Miller, the team molded pieces of PLGA, a biodegradable polymer often used for blood vessel grafts, so they came out completely covered with bumps that were 100, 200 or 500 nanometers in diameter. The surface with 200-nanometer features strongly favored the adsorption and spreading of fibronectin, a protein that helps endothelial cells quickly coat the graft.

Webster and Haberstroh's next step will be to test such nanostructured implants in live animals. If the same behavior holds true for materials placed in the body, the rapid growth of endothelial cells would help the implants to integrate quickly into existing blood vessels, provoking less immune response and a longer-lasting repair.

Source: Brown University

Explore further: Flower-like magnetic nanoparticles target difficult tumors

add to favorites email to friend print save as pdf

Related Stories

New nanogel for drug delivery

Feb 19, 2015

Scientists are interested in using gels to deliver drugs because they can be molded into specific shapes and designed to release their payload over a specified time period. However, current versions aren't ...

Avian malaria also affects wild birds in Austria

Feb 10, 2015

Avian malaria is not uncommon in Central Europe, as many endemic wild birds are infected with species of Plasmodium, which cause avian malaria. In most cases these blood parasites, transmitted by mosquitoes, ...

Engineers put the 'squeeze' on human stem cells

Feb 10, 2015

After using optical tweezers to squeeze a tiny bead attached to the outside of a human stem cell, researchers now know how mechanical forces can trigger a key signaling pathway in the cells.

3-D printers to make human body parts? It's happening

Feb 04, 2015

It sounds like something from a science fiction plot: So-called three-dimensional printers are being used to fashion prosthetic arms and hands, jaw bones, spinal-cord implants - and one day perhaps even living human body ...

Recommended for you

Electrons moving along defined snake states

21 hours ago

Physicists at the University of Basel have shown for the first time that electrons in graphene can be moved along a predefined path. This movement occurs entirely without loss and could provide a basis for ...

New nanodevice defeats drug resistance

Mar 02, 2015

Chemotherapy often shrinks tumors at first, but as cancer cells become resistant to drug treatment, tumors can grow back. A new nanodevice developed by MIT researchers can help overcome that by first blocking ...

Glass coating improves battery performance

Mar 02, 2015

Lithium-sulfur batteries have been a hot topic in battery research because of their ability to produce up to 10 times more energy than conventional batteries, which means they hold great promise for applications ...