Sorting device for analyzing biological reactions puts the power of a lab in a researcher’s pocket (w/ Video)

Mar 02, 2010
The microfluidic sorting device removes inactive and unwanted compounds, dumping the drops into a "bad egg" bin, and guides the others into a "keep" container. Specifically, as the drops flow through the channels they eventually encounter a junction (a two-channel fork). The device identifies the desired drops by using a laser focused on the channel before the fork to read a drop's fluorescence level. The drops with greater intensity of fluorescence (those exhibiting the highest levels of activity) are pulled towards the keep channel by the application of an electrical force, a process known as dielectrophoresis. Credit: Courtesy of Jeremy Agresti, Harvard School of Engineering and Applied Sciences.

Fictional candy maker Willy Wonka called his whimsical device to sort good chocolate eggs from bad, an eggucator. Likewise, by determining what enzymes and compounds to keep and which to discard, scientists are aiming to find their own golden eggs: more potent drugs and cleaner sources of energy.

Toward that end, Harvard researchers and a team of international collaborators demonstrated a new microfluidic sorting device that rapidly analyzes millions of biological reactions. Smaller than an iPod Nano, the device analyzes reactions a 1,000-times faster and uses 10 million-fold less volumes of reagent than conventional state-of-the-art robotic methods.

The scientists anticipate that the invention could reduce screening costs by 1 million-fold and make directed evolution, a means of engineering tailored biological compounds, more commonplace in the lab.

"Our finding is not so much a , but the first demonstration of a new technology," says project leader Jeremy Agresti, a former research associate in the lab of co-author David Weitz, Mallinckrodt Professor of Physics and of Applied Physics in the Harvard School of Engineering and Applied Sciences (SEAS) and Department of Physics. "What limits new areas of research in biology and biotechnology is the ability to assay or to do experiments on many different variables in parallel at once."

This video is not supported by your browser at this time.
The sorted drops move up the field gradient created by the electrodes by dielectrophoresis and are pulled into the keep channel. The movie is recorded at 4,000 frames s-1 and shows the result of sorting a demonstration emulsion containing fluorescein (light drops) or bromophenol blue 1 percent by weight in water. Credit: Jeremy Agresti, Harvard School of Engineering and Applied Sciences

The team's technology, first reported in the February 8th online Early Edition of the , bypasses conventional limitations through the use of drop-based microfluidics, squeezing tiny capsules of liquid through a series of intricate tubes, each narrower than a single human hair.

"Each microscopic drop can trap an individual cell and thus it becomes like a miniature test tube," explains Amy Rowat, a postdoctoral fellow at SEAS. "The drops are coated with a surfactant, or stabilization molecule, that prevents the drops from coalescing with each other and also prevents the contents from sticking to the wall of the drops."

To sort, the system removes inactive and unwanted compounds, dumping the drops into a "bad egg" bin, and guides the others into a "keep" container. Specifically, as the drops flow through the channels they eventually encounter a junction (a two-channel fork). Left alone, the drops will naturally flow towards the path of least fluidic resistance, or the waste channel.

The device identifies the desired drops by using a laser focused on the channel before the fork to read a drop's fluorescence level. The drops with greater intensity of fluorescence (those exhibiting the highest levels of activity) are pulled towards the keep channel by the application of an electrical force, a process known as dielectrophoresis.

"Our concept was to build a miniature laboratory for performing biological experiments quickly and efficiently," explains collaborator Adam Abate, a postdoctoral fellow in applied physics at SEAS. "To do this we needed to construct microfluidic versions of common bench-top tasks, such as isolating cells in a compartment, adding reagents, and sorting the good from the bad. The challenge was to do this with microscopic drops flowing past at thousands per second."

"The sorting process is remarkably efficient and fast. By shrinking down the reaction size to 10 picoliters of volumes, we increased the sorting speed by the same amount," adds Agresti. "In our demonstration with horseradish peroxidase, we evolved and improved an already efficient enzyme by sorting through 100 million variants and choosing the best among them."

In particular, the researchers were struck by the ability to increase the efficiency of an already efficient enzyme to near its theoretical maximum, the diffusion limit, where the enzyme can produce products as quickly as a new substrate can bump into it.

Using conventional means, the sorting process would have taken several years. Such a dramatic reduction of time could be a boon for the burgeoning field of synthetic biology. For example, a biofuels developer could use the device to screen populations of millions of organisms or metabolic pathways to find the most efficient producer of a chemical or fuel. Likewise, scientists could speed up the pace of drug development, determining the best chemical candidate compounds and then evolving them based upon desired properties.

"The high speed of our technique allows us to go through multiple cycles of mutation and screening in a very short time," says Agresti. "This is the way evolution works best. The more generations you can get through, the faster you can make progress."

Explore further: Researchers create designer 'barrel' proteins

Related Stories

Microfluidic Device Tests Fluid Compatibility

Apr 14, 2006

The key to a great party is inviting guests who mix well and don't instill tension among their fellow revelers. The key to a great detergent, cosmetic, paint or other complex liquid product is pretty much the ...

Make your own microfluidic device with new kit from U-M

Jul 24, 2008

A type of device called a "lab-on-a-chip" could bring a new generation of instant home tests for illnesses, food contaminants and toxic gases. But today these portable, efficient tools are often stuck in the lab themselves. ...

Nano drops from the one-way pack

Sep 15, 2004

New dispenser system made of plastic reduces costs for use of micro dispensers A two-component micro dispenser system developed at the Institut für Mikrotechnik Mainz GmbH (IMM) produces nano drops ...

Recommended for you

Amino acids key to new gold leaching process

22 hours ago

Curtin University scientists have developed a gold and copper extraction process using an amino acid–hydrogen peroxide system, which could provide an environmentally friendly and cheaper alternative to ...

Researchers create designer 'barrel' proteins

Oct 23, 2014

Proteins are long linear molecules that fold up to form well-defined 3D shapes. These 3D molecular architectures are essential for biological functions such as the elasticity of skin, the digestion of food, ...