NIST researchers 'all aglow' over new test of toxin strength

Jun 17, 2009
Microscopic photographs showing the level of fluorescence (green images on left) and the numbers of cells (blue images on right) at the time the cells were exposed to ricin (top row) and six hours later (bottom row). Note that the fluorescence has decreased (more black regions in the bottom left photo) while the cell count remains virtually the same. This shows that the NIST assay detects ricin even before significant cell death occurs. Credit: M. Halter, NIST

A new National Institute of Standards and Technology (NIST) assay using a “glow or no glow” technique may soon help the U.S. Department of Homeland Security (DHS) defend the nation against a spectrum of biological weapons that could be used in a terrorist attack. One very dangerous toxin on the list is ricin, a protein derived from castor beans that is lethal in doses as small as 500 micrograms—about the size of a grain of salt.

As part of its efforts to address the threat, DHS is working with NIST to create a standardized ricin sample with a known potency. Such a standard is needed both to check the accuracy of detection equipment, and, should an attack occur, to confirm the success of decontamination procedures. A major step toward this goal—the development of a rapid, reliable and precise assay of the potency of a ricin sample—has now been achieved by NIST scientists.

As detailed in an article posted online this week in Assay and Drug Development Technologies, the new NIST assay uses a commercially available cell line genetically engineered to produce large amounts of green fluorescent protein (GFP). Ricin shuts down ribosomes—the protein manufacturing factories of a cell. Assay cells exposed to the toxin will quickly stop synthesizing GFP. This, in turn, will result in a measurable decrease in fluorescence—a drop that correlates directly to the strength of the ricin present.

The NIST assay yields many advantages over traditional cytotoxicity measuring systems, including: a highly sensitive response to ricin (as little as 1 nanogram per milliliter) within six rather than 24 hours; detection of the toxin long before significant cell death has occurred; results that are highly reproducible; no need for the addition of any reagents; and the flexibility to measure the potency of other ribosome inhibitors, even nanoparticles, with the same precision as ricin.

Citation: M. Halter, J.L. Almeida, A. Tona, K.D. Cole, A.L. Plant and J.T. Elliott. A mechanistically relevant cytotoxicity assay based on the detection of cellular green fluorescent protein. Assay and Drug Development Technologies, Vol. 7, No. 4 (August 2009; posted online the week of June 15, 2009).

Source: National Institute of Standards and Technology (NIST)

Explore further: Neutron tomography technique reveals phase fractions of crystalline materials in 3-dimensions

add to favorites email to friend print save as pdf

Related Stories

What are protective effects of anti-ricin A-chain aptamer?

Dec 29, 2008

Ricin, a lectin from the castor bean plant Ricinus communis is considered one of the most potent plant toxins. Ricin poisoning can cause severe tissue damage and inflammation and can result in death. Most accidental exposures ...

Researchers devise a fast and sensitive way to detect ricin

Apr 08, 2009

Scientists at Albert Einstein College of Medicine of Yeshiva University have developed a simple, accurate, and highly sensitive test to detect and quantify ricin, an extremely potent toxin with potential use as a bioterrorism ...

Ricin's deadly action revealed by glowing probes

Aug 07, 2008

A new chemical probe can rapidly detect ricin, a deadly poison with no known antidote that is feared to be a potential weapon for terrorists and cannot quickly be identified with currently available tests.

Quantum dots to be explored for use as fluorescent standards

Aug 24, 2004

Evident Technologies, Inc. announced today that it has entered into a Cooperative Research and Development Agreement (CRADA) with the National Institute of Standards and Technology (NIST) to explore the use of quantum dot composite fluorescent standards ...

Recommended for you

50-foot-wide Muon g-2 electromagnet installed at Fermilab

11 hours ago

One year ago, the 50-foot-wide Muon g-2 electromagnet arrived at the U.S. Department of Energy's Fermi National Accelerator Laboratory in Illinois after traveling 3,200 miles over land and sea from Long Island, ...

Spin-based electronics: New material successfully tested

Jul 30, 2014

Spintronics is an emerging field of electronics, where devices work by manipulating the spin of electrons rather than the current generated by their motion. This field can offer significant advantages to computer technology. ...

User comments : 1

Adjust slider to filter visible comments by rank

Display comments: newest first

COCO
not rated yet Jun 18, 2009
these clowns are as likely to be involved with another false flag op that their opinions on toxicity hopefully are written as well as their sophmoric tome on the 911 incident.