Pressure sensors in the eye

Sep 03, 2007
Pressure sensors in the eye
On the edge of the artificial lens is a 2.5 by 2.6 millimeter sensor that measures intraoptical pressure. © Fraunhofer IMS

Sensors can monitor production processes, unmask tiny cracks in aircraft hulls, and determine the amount of laundry in a washing machine. In future, they will also be used in the human body and raise the alarm in the event of high pressure in the eye, bladder or brain.

If the pressure in the eye is too high, nerve fibers die, resulting in visual field loss or blindness. Since increased intraocular pressure, also known as glaucoma, is not usually painful, the condition is often diagnosed too late. Moreover, such patients often tend to develop cataracts when they get older – the lenses of their eyes become opaque.

In such cases, surgeons remove the natural lens and replace it with an artificial one. To avoid further loss of nerve fibers, the intraocular pressure is then regulated as accurately as possible with the help of medication. Unfortunately, the pressure continues to vary despite medication, obligating the patient to have it constantly monitored by physicians and the medication dosage adjusted accordingly.

In future, a sensor developed by researchers at the Fraunhofer Institute for Microelectric Circuits and Systems IMS in Duisburg will obviate the need for constant visits to the physician by such patients. “We integrate the 2.5 by 2.6 millimeter sensor in the artificial lens,” says Thomas van den Boom, group manager for biohybrid systems at the IMS. “This doesn’t impair the patient’s vision.”

The top and bottom of the sensor are formed by electrodes; the top electrode is flexible, in contrast to its rigid counterpart on the bottom of the sensor. When the intraocular pressure increases, the top electrode is pushed in, reducing the distance between the top and bottom of the sensor and thus increasing the capacitance.

Using a tiny antenna, the implant then sends the pressure data to a reader that is fitted into the frame of a pair of spectacles. The patient can view the results on an auxiliary device and determine whether the pressure has reached a critical level. An antenna in the spectacle frame supplies the sensor with the required energy via an electromagnetic field. “The power consumption of the sensor must be kept to an absolute minimum,” explains van den Boom. “All unused components are put in a kind of standby mode and only activated when needed.”

The permanent eye implant is currently undergoing clinical trials and could come into general use in two to three years’ time. But the sensor is not only suitable for use in the eye: When implanted in blood vessels in the thigh or the upper arm it can also help patients with chronic hypertension. “Conventional devices for measuring blood pressure at home are not suitable for determining the correct medication dosage,” says van den Boom. The sensor is also expected to benefit patients suffering from increased intracranial pressure or those with incontinence problems.

Source: Fraunhofer-Gesellschaft

Explore further: Lockheed Martin advances live, virtual, constructive training in flight test

add to favorites email to friend print save as pdf

Related Stories

Apple helps iTunes users delete free U2 album

42 minutes ago

Apple on Monday began helping people boot U2 off their iTunes accounts after a cacophony of complaints about not wanting the automatically downloaded free album by the Irish rock band.

Recommended for you

Reducing traffic congestion, remotely

Sep 16, 2014

At the Intelligent Transportation Systems World Congress last week, MIT researchers received one of the best-paper awards for a new system, dubbed RoadRunner, that uses GPS-style turn-by-turn directions to ...

How to print your own cell phone microscope for pennies

Sep 16, 2014

At one o'clock in the morning, layers of warm plastic are deposited on the platform of the 3D printer that sits on scientist Rebecca Erikson's desk. A small plastic housing, designed to fit over the end of ...

User comments : 0