3-D-printed polymer stents grow with pediatric patients and biodegrade over time

May 18, 2017
Credit: Mary Ann Liebert, Inc., publishers

A new study demonstrates proof-of-concept for combining computational design and simulation tools with 3D printing technology to produce self-expandable polymer stents that can grow with pediatric patients, are biodegradable, and require only a minimally-invasive procedure for implantation. This innovative method is described in an article in 3D Printing and Additive Manufacturing.

M.S. Cabrera, B. Sanders, O.J.G.M. Goor, A. Driessen-Mol, C.W.J. Oomens, and F.P.T. Baaijens, Eindhoven University of Technology, the Netherlands, coauthored the study entitled "Computationally Designed 3D Printed Self-Expandable Polymer Stents with Biodegradation Capacity for Minimally-Invasive Heart Valve Implantation: A Proof of Concept Study."

To overcome the current challenges in designing bioabsorbable polymer stents with the necessary for use in minimally invasive procedures to implant tissue-engineered heart valves in young patients, researchers have developed a novel approach to create stents with growth potential and a sufficient degree of plastic deformation. The rapid prototyping method they describe involves creating an in silico model of a conventional nitinol stent and then translating the computational simulation into prototype stents using 3D printing and a flexible copolyester elastomer. The authors evaluated the mechanical properties of the by subjecting them to crush and crimping tests, and performed accelerated degradation tests to assess their biodegradability.

Explore further: 3-D printing customized vascular stents

More information: María Sol Cabrera et al, Computationally Designed 3D Printed Self-Expandable Polymer Stents with Biodegradation Capacity for Minimally Invasive Heart Valve Implantation: A Proof-of-Concept Study, 3D Printing and Additive Manufacturing (2017). DOI: 10.1089/3dp.2016.0052

Related Stories

Results from the BIO-RESORT trial presented

October 31, 2016

Results of a large-scale, multicenter study found that treatment with two thin-strut drug-eluting stents were both non-inferior to a durable polymer drug-eluting stent and showed favorable clinical outcomes at one year in ...

Drug-Eluting stents reduce risk of thrombosis

March 23, 2012

(HealthDay) -- Cobalt-chromium everolimus eluting stents (CoCr-EES) are associated with a significantly lower rate of stent thrombosis within two years of implantation, compared with other bare-metal and drug-eluting stents, ...

Results from the tranform-oct study reported

November 7, 2016

Results from TRANSFORM-OCT, a prospective, randomized trial using optical coherence tomography (OCT) to evaluate strut coverage and neoatherosclerosis (NA) found that bioresorbable polymer-based drug-eluting stents (BP-EES) ...

Recommended for you

Utrecht chemists prove Nobel Prize-winner Olah correct

November 21, 2017

In 1877, Charles Friedel and James Craft discovered a chemical reaction for quickly producing raw materials for plastics, fine chemicals and detergents. More than 100 years later, in 1994, the American George Olah won the ...

Artificial photosynthesis gets big boost from new catalyst

November 20, 2017

A new catalyst created by U of T Engineering researchers brings them one step closer to artificial photosynthesis—a system that, just like plants, would use renewable energy to convert carbon dioxide (CO2) into stored chemical ...

0 comments

Please sign in to add a comment. Registration is free, and takes less than a minute. Read more

Click here to reset your password.
Sign in to get notified via email when new comments are made.