NASA Plans Test of 'Electronic Nose' on International Space Station

Nov 19, 2008

NASA astronauts on space shuttle Endeavour's STS-126 mission will install an instrument on the International Space Station that can "smell" dangerous chemicals in the air. Designed to help protect crew members' health and safety, the experimental "ENose" will monitor the space station's environment for harmful chemicals such as ammonia, mercury, methanol and formaldehyde.

The ENose fills the long-standing gap between onboard alarms and complex analytical instruments. Air-quality problems have occurred before on the International Space Station, space shuttle and Russian Space Station Mir. In most cases, the chemicals were identified only after the crew had been exposed to them, if at all. The ENose, which will run continuously and autonomously, is the first instrument on the station that will detect and quantify chemical leaks or spills as they happen.

"The ENose is a 'first-responder' that will alert crew members of possible contaminants in the air and also analyze and quantify targeted changes in the cabin environment," said Margaret A. Ryan, the principal investigator of the ENose project at NASA's Jet Propulsion Laboratory, or JPL, in Pasadena, Calif. JPL built and manages the device.

Station crew members will unpack the ENose on Dec. 9 to begin the instrument's six-month demonstration in the crew cabin. If the experiment is successful, the ENose might be used in future space missions as part of an automated system to monitor and control astronauts' in-space environments.

"This ENose is a very capable instrument that will increase crew awareness of the state of their air quality," said Carl Walz, an astronaut and director of NASA's Advanced Capabilities Division, part of the Exploration System Mission Directorate, which funds the ENose. "Having experienced an air-quality issue during my Expedition 4 mission on the space station, I wish I had the information that this ENose will provide future crews. This technology demonstration will provide important information for environmental control and life-support system designers for the future lunar outpost."

Specifically, the shoebox-sized ENose contains an array of 32 sensors that can identify and quantify several organic and inorganic chemicals, including organic solvents and marker chemicals that signal the start of electrical fires. The ENose sensors are polymer films that change their electrical conductivity in response to different chemicals. The pattern of the sensor array's response depends on the particular chemical types present in the air.

The instrument can analyze volatile aerosols and vapors, help monitor cleanup of chemical spills or leaks, and enable more intensive chemical analysis by collecting raw data and streaming it to a computer at JPL's ENose laboratory. The instrument has a wide range of chemical sensitivity, from fractional parts per million to 10,000 parts per million. For all of its capabilities, the ENose weighs less than nine pounds and requires only 20 watts of power.

The ENose is now in its third generation. The first ENose was tested during a six-day demonstration on the STS-95 shuttle mission in 1998. That prototype could detect 10 compounds, but could not analyze data immediately. The second-generation ENose could detect, identify and quantify 21 different chemicals. It was extensively ground-tested. The third-generation ENose includes data-analysis software to identify and quantify the release of chemicals within 40 minutes of detection. While it will look for 10 chemical types in this six-month experiment, the new ENose can be trained to detect many others.

For more information about the ENose and the Advanced Environmental Monitoring and Control Project, visit: aemc.jpl.nasa.gov/instruments/enose.cfm

Provided by NASA

Explore further: Curiosity brushes 'Bonanza king' target anticipating fourth red planet rock drilling

add to favorites email to friend print save as pdf

Related Stories

The 'Nose' Knows

Jan 12, 2010

(PhysOrg.com) -- Some might say it's as plain as the nose on your face. But detecting toxic or dangerous chemicals in the microgravity environment of space takes a little extra "sniffing." That’s why ENose, ...

Recommended for you

Australian amateur Terry Lovejoy discovers new comet

13 hours ago

It's confirmed! Australian amateur astronomer Terry Lovejoy just discovered his fifth comet, C/2014 Q2 (Lovejoy). He found it August 17th using a Celestron C8 fitted with a CCD camera at his roll-off roof ...

Students see world from station crew's point of view

Aug 19, 2014

NASA is helping students examine their home planet from space without ever leaving the ground, giving them a global perspective by going beyond a map attached to a sphere on a pedestal. The Sally Ride Earth ...

Mars deep down

Aug 19, 2014

Scarring the southern highlands of Mars is one of the Solar System's largest impact basins: Hellas, with a diameter of 2300 km and a depth of over 7 km.

User comments : 1

Adjust slider to filter visible comments by rank

Display comments: newest first

denijane
not rated yet Nov 25, 2008
I just hope that they won't connect it to any failsafe system, because it reminds me of the latest accident on Russian submarine. Although this accident was claimed to be a human mistake, it still ring an important bell about the safety of such closed spaces.