Clean Room Classic: Vacuum Evaporator Purchased 50 Years Ago Still Going Strong

Nov 20, 2007
Clean Room Classic: Vacuum Evaporator Purchased 50 Years Ago Still Going Strong
Carefully maintained and updated, a 50-year-old vacuum evaporator is still applying coatings in a Georgia Tech Research Institute clean room. Photo: Gary Meek, Georgia Tech

A 1957 classic sits in the Georgia Tech Research Institute (GTRI) clean room. It’s not a Chevy, but a Veeco vacuum evaporator more than six feet tall and five feet wide.

The evaporator, still in use today, deposits thin films necessary for microfabrication processes. Applications include creating the reflective or anti-reflective coatings on optics and building up layers of insulators, semiconductors and conductors to form integrated electronic circuits.

“It’s a very rugged machine and it’s gotten better with age,” said Mike Harris, a principal research engineer in GTRI's Electro-Optical Systems Lab. Harris first used the Model 775 evaporator in 1972 as a student.

The system operates by evaporating a source material, such as a metal, in a high vacuum, allowing vapor particles to travel directly to a target object, such as a semiconductor, where they condense back to a solid state and form a thin film of the source material.

Harris attributes the machine’s longevity to its design and documentation – and to the skills of GTRI technicians and engineers. “The operator and maintenance manuals are excellent, with exploded views of the various piece parts, making it very easy for our technicians and engineers to repair it when we have problems,” he explained.

In addition to repairing the system, GTRI engineers have upgraded and modified the evaporator several times since it was purchased.

First, they changed the high vacuum pump from a diffusion pump to a more modern cryogenic pump in 2002. The diffusion pump generated a high speed jet of vapor by boiling fluid and directing the vapor in the pump throat down into the bottom of the pump and out the exhaust. The newer cryogenic pump traps gases and vapors by condensing them on a cold surface.

To increase the uniformity of results, GTRI researchers added a planetary substrate fixture that rotates inside the evaporation chamber.

In addition, the original system was designed with a tungsten filament that was heated to a high enough temperature so that the source material placed in a crucible on the filament evaporated. GTRI engineers changed this to an electron beam evaporator that fires a high-energy beam from an electron gun to boil a small spot of material, allowing lower vapor pressure materials to be deposited.

Since the 1957 system still runs and remains optimal for numerous applications, Harris sees no reason to buy a new one. “New systems like this probably cost between $700,000 and $1 million,” he added. “And the new systems are designed primarily for throughput and that’s not necessarily best for a research environment.”

Source: Georgia Institute of Technology, by Abby Vogel

Explore further: Physicists use magnetism simulation software to model US presidential elections

add to favorites email to friend print save as pdf

Related Stories

Recommended for you

Using antineutrinos to monitor nuclear reactors

18 hours ago

When monitoring nuclear reactors, the International Atomic Energy Agency has to rely on input given by the operators. In the future, antineutrino detectors may provide an additional option for monitoring. ...

Imaging turns a corner

22 hours ago

(Phys.org) —Scientists have developed a new microscope which enables a dramatically improved view of biological cells.

Mapping the road to quantum gravity

Apr 23, 2014

The road uniting quantum field theory and general relativity – the two great theories of modern physics – has been impassable for 80 years. Could a tool from condensed matter physics finally help map ...

User comments : 2

Adjust slider to filter visible comments by rank

Display comments: newest first

hudres
5 / 5 (1) Nov 20, 2007
While this may seem impressive, by replacing the high vacuum pump and adding the planetary fixture, they upgraded it to a more or less current configuration. Big deal! All this proves is that a glass bell jar doesn't leak after all this time. I have many old system in my lab. They get upgraded and are essentially like new. Now, what is really impressive is the 1903 vacuum tube in my collection that still has its original vacuum and works as well as the day to was built. No rebuilds, just a simple chemical getter pump and really good processing when the tube was built. I gave it a 5 anyway
quantum_flux
not rated yet Nov 20, 2007
There are still functioning Ford Model T's and Model A's in the world, but they aren't owned by the government. The real achievement here is building a machine that can survive for long periods of time in a beauracracy.

More news stories

Phase transiting to a new quantum universe

(Phys.org) —Recent insight and discovery of a new class of quantum transition opens the way for a whole new subfield of materials physics and quantum technologies.

When things get glassy, molecules go fractal

Colorful church windows, beads on a necklace and many of our favorite plastics share something in common—they all belong to a state of matter known as glasses. School children learn the difference between ...

How do liquid foams block sound?

Liquid foams have a remarkable property: they completely block the transmission of sound over a wide range of frequencies. CNRS physicists working in collaboration with teams from Paris Diderot and Rennes ...

Google+ boss leaving the company

The executive credited with bringing the Google+ social network to life is leaving the Internet colossus after playing a key role there for nearly eight years.