Breaking the barrier toward nanometer X-ray resolution

Sep 29, 2007
Breaking the barrier toward nanometer X-ray resolution
The research team at NSLS beamline X13B, from left: James Ablett, Aaron Stein, and Kenneth Evans-Lutterodt.

A team of researchers at the U.S. Department of Energy’s Brookhaven National Laboratory have overcome a major obstacle for using refractive lenses to focus x-rays. This method will allow the efficient focusing of x-rays down to extremely small spots and is an important breakthrough in the development of a new, world-leading light source facility that promises advances in nanoscience, energy, biology, and materials research.

At Brookhaven’s National Synchrotron Light Source (NSLS), the scientists exceeded a limit on the ability to focus “hard,” or high-energy, x-rays known as the “critical angle.” Their results are described online in the September 28, 2007, edition of Physical Review Letters.

The critical angle is the maximum angle that light can be deflected, or bent, by a single surface. Imagine a beam of laser light traveling toward a glass lens. Depending on the characteristics of the lens material and the angle at which the beam is pointed, the light can be refracted, that is, transmitted through the lens but deflected. However, when this light approaches the lens at angles less than the critical angle, the beam does not pass through the lens but is instead reflected. This results in a maximum deflection angle for light that passes through the lens.

The maximum deflection angle determines the minimum spot size to which x-rays can be focused. This poses a problem for researchers who are using x-rays to study molecules, atoms, and advanced materials at the nanoscale – on the order of billionths of a meter. Such small subjects require tightly focused beams.

“One measure of the quality of an x-ray optic is how small a focused spot it can make,” said NSLS researcher Ken Evans-Lutterodt. “The problem is that nature does not allow a single lens to deflect the x-rays very much. This limits how small of a spot you can create, and this translates to some fuzziness in the image. To get a sharper image, you need a lens that’s more able to deflect the x-rays.”

In 2003, a trio of Brookhaven researchers – Evans-Lutterodt, Aaron Stein, and James Ablett – were the first to notice the critical angle limit while investigating the properties of a so-called kinoform lens for focusing hard x-rays. This efficient type of refractive lens is similar to those found in lighthouses. The research team proposed a solution to the critical angle problem of a compound kinoform lens, and both the problem and proposed solution were also suggested later by other researchers in the field.

In the current publication, the researchers implemented their idea by creating a compound lens from a series of four kinoform lenses placed one after the other. Using this setup at NSLS beamline X13B, they showed that the critical angle can be surpassed with hard x-rays, while still focusing like a single lens.

“Thanks to the excellent fabrication resources at Brookhaven’s Center for Functional Nanomaterials and at Alcatel-Lucent, we are able to fabricate the lenses to the precision required,” Stein said.

This is an important step for the National Synchrotron Light Source II (NSLS-II), a state-of-the-art synchrotron facility that will produce x-rays up to 10,000 times brighter than those generated by the current NSLS and could lead to advances such as alternative-energy technologies and new drugs for fighting disease. One of the major goals of the facility is to probe materials and molecules with just one-nanometer resolution – a capability needed to study the intricate mechanisms of chemical and biological systems.

“Without exceeding the critical angle, the refractive lens resolution would be limited to 24 nanometers or more,” Ablett said. “Even though in this experiment we just barely exceeded this limit, we’ve shown that it can be done. This is just the first step.”

Next, the researchers will measure the resolution their new lens system produces, and will continue to fabricate and test optics that push further beyond the critical angle, and closer to the one-nanometer benchmark.

“We’ve broken the barrier, now there’s still more work to be done to get down to those small x-ray spots,” Evans-Lutterodt said. “Hopefully this will be one of the routes that NSLS-II and others will use.”

Source: Brookhaven National Laboratory

Explore further: Engineers develop new methods to speed up simulations in computational grand challenge

add to favorites email to friend print save as pdf

Related Stories

Recommended for you

New insights found in black hole collisions

1 hour ago

New research provides revelations about the most energetic event in the universe—the merging of two spinning, orbiting black holes into a much larger black hole.

X-rays probe LHC for cause of short circuit

1 hour ago

The LHC has now transitioned from powering tests to the machine checkout phase. This phase involves the full-scale tests of all systems in preparation for beam. Early last Saturday morning, during the ramp-down, ...

Swimming algae offer insights into living fluid dynamics

4 hours ago

None of us would be alive if sperm cells didn't know how to swim, or if the cilia in our lungs couldn't prevent fluid buildup. But we know very little about the dynamics of so-called "living fluids," those ...

Fluctuation X-ray scattering

Mar 26, 2015

In biology, materials science and the energy sciences, structural information provides important insights into the understanding of matter. The link between a structure and its properties can suggest new ...

Hydrodynamics approaches to granular matter

Mar 26, 2015

Sand, rocks, grains, salt or sugar are what physicists call granular media. A better understanding of granular media is important - particularly when mixed with water and air, as it forms the foundations of houses and off-shore ...

User comments : 1

Adjust slider to filter visible comments by rank

Display comments: newest first

Ibeltimes
not rated yet Oct 04, 2007
Critical angle utilization,may be the solution for subatom studies,if the wavelength it is small enough.Ibeltimes

Please sign in to add a comment. Registration is free, and takes less than a minute. Read more

Click here to reset your password.