Thumb-size microsystem enables cell culture and incubation

Oct 02, 2007
Thumb-size microsystem enables cell culture and incubation
Johns Hopkins researchers have developed this thumb-sized microincubator. A syringe is used to inject living cells and nutrients into the device. Credit: Will Kirk/JHU

Integrating silicon microchip technology with a network of tiny fluid channels, some thinner than a human hair, researchers at The Johns Hopkins University have developed a thumb-size micro-incubator to culture living cells for lab tests.

In a recent edition of the journal IEEE Transactions on Biomedical Circuits and Systems, the Johns Hopkins researchers reported that they had successfully used the micro-incubator to culture baby hamster kidney cells over a three-day period. They said their system represents a significant advance over traditional incubation equipment that has been used in biology labs for the past 100 years.

“We don’t believe anyone has made a system like this that can culture cells over a period of days autonomously,” said Jennifer Blain Christen, lead author of the journal article. “Once it’s set up, you can just walk away.”

The incubator’s microchannels, fabricated in soft silicone polymer material, allow researchers to easily insert and guide cells and nutrients during experiments, while the computer-controlled electronics keep the cells at the precise temperature that enables them to multiply and thrive. The tiny incubator’s transparent design makes it easy to view the cells through a microscope or camera equipment without disrupting the conditions that help the cells to flourish.

Blain Christen spent the past three years working on the device as the focus of her doctoral dissertation in the Department of Electrical and Computer Engineering in Johns Hopkins’ Whiting School of Engineering. She received her degree in May and has continued to fine-tune the device while working as a postdoctoral fellow.

Andreas G. Andreou, a professor in the Department of Electrical and Computer Engineering who served as Blain Christen’s doctoral adviser, said, “This device represents a unique blend of two technologies, and we believe it will have a great impact on biology lab testing and research.” Andreou was co-author on the journal article.

Since the early 20th century, cell culture techniques in biology labs have remained largely unchanged. Living cells and nutrients are put into a lab dish and then are placed inside a traditional incubator, a heating compartment that is typically the size of a small refrigerator. Within the unit, the researcher must maintain a constant temperature, an environment free of contaminants and the proper levels of humidity, oxygen and carbon dioxide. Whenever the lab dish is removed for observation or experiments, however, these optimal conditions are disrupted, and the cells begin to die.

In contrast, the thumb-size system developed by the Johns Hopkins engineers is self-contained and requires no external heating source. A drop of liquid containing living cells is injected into a port and flows through one of the microfluidic channels. A nutrient solution — the cells’ food – is also added in this manner.

The cells gravitate toward and stick to the surface of the microchip. The chip contains a simple heating unit – a miniature version of the type found in a common toaster – and is equipped with a sensor that continually checks to make sure the proper temperature is maintained. For human cells, this is usually 37 degrees Celsius or 98.6 degrees Fahrenheit. The chip is connected to a computer that controls the sensing and heating process. The prototype is connected to a computer via a hard wire, but the inventors say a wireless version would be the next step.

A gas-permeable membrane on the incubator allows the microsystem to exchange carbon dioxide and oxygen but keeps out bacteria that could contaminate the cell culture. If a cell colony grows too large, an enzyme can be injected into one of the microfluidic ports to detach and flush away surplus cells without destroying the primary cell culture.

The incubator’s small size provides several advantages, the researchers say. The unit can easily be moved to different microscopes, imaging devices or other experimental tools without jeopardizing the health of the cell culture. Its size and relatively low cost should allow biologists to run numerous experiments simultaneously in a small space. Because it can be powered by batteries, the micro-incubator could be used outside a traditional lab for field tests. “Also,” said Blain Christen, “because it’s so small, we can change the temperature of the cell culture environment very quickly. We can go from room temperature to 98.6 degrees in less than a 10th of a second.”

The device was designed not only to provide these capabilities but to do so in an eco-friendly manner. This was achieved by minimizing the size of components whose fabrication affects the environment in an adverse way. These components were also designed so that they can easily be re-used in other devices. Blain Christen and Andreou said environmental impacts should be an important consideration in all types of research. “In our own field, among researchers who are working at the interface between electronics and biology, we believe our approach – making ecological considerations integral to our design – is rather uncommon,” said Blain Christen. “But we also believe this approach is one that all engineers should be adopting.”

Blain Christen and Andreou are continuing to refine and enhance the micro-incubator. They say they hope to enable it to image the cells and tissue using optical light guides, and that they wish to give it the ability to stimulate and gather information about the electrical activity of cells.

Source: Johns Hopkins University

Explore further: Ninety-eight new beetle species discovered in Indonesia

add to favorites email to friend print save as pdf

Related Stories

Stem cells born out of indecision

Dec 18, 2014

Scientists at the University of Copenhagen have gained new insight into embryonic stem cells and how blocking their ability to make choices explains why they stay as stem cells in culture. The results have just been published ...

Virus causing mass Cape Cod duck die-offs identified

Dec 16, 2014

Since 1998, hundreds and sometimes thousands of dead eider ducks have been washing up every year on Cape Cod's beaches in late summer or early fall, but the reasons behind these cyclic die-offs have remained ...

NIST suggests new purity test for biotech products

Dec 03, 2014

To avoid contaminating their experiments, biomedical researchers want to know that the scientific products they buy are pure. But how pure does something need to be to really be pure? Using a new test, scientists ...

Teaching robots to see

Dec 15, 2014

Syed Saud Naqvi, a PhD student from Pakistan, is working on an algorithm to help computer programmes and robots to view static images in a way that is closer to how humans see.

Recommended for you

Ninety-eight new beetle species discovered in Indonesia

52 minutes ago

Ninety-eight new species of the beetle genus Trigonopterus have been described from Java, Bali and other Indonesian islands. Museum scientists from Germany and their local counterparts used an innovative approa ...

Bacteria are wishing you a Merry Xmas

1 hour ago

A bacterium has been used to wish people a Merry Xmas. Grown by Dr Munehiro Asally, an Assistant Professor at the University of Warwick, the letters used to spell MERRY XMAS are made of Bacillus subtilis, ...

Pragmatic approach to saving what can be saved

1 hour ago

How can biodiversity be preserved in a world in which traditional ecosystems are increasingly being displaced by "man-made nature"? Biologists at the TU Darmstadt and ETH Zurich have developed a new concept ...

User comments : 0

Please sign in to add a comment. Registration is free, and takes less than a minute. Read more

Click here to reset your password.
Sign in to get notified via email when new comments are made.