Largest study to date finds benefits of ICDs in children

May 01, 2008

More and more children with congenital heart disease are receiving implantable cardioverter-defibrillators (ICDs) to maintain proper heart rhythm. ICDs were first introduced for adults in the 1980s, but little is known about how well they work in children, who account for less than 1 percent of recipients.

A report in the April 29 Journal of the American College of Cardiology summarizes the largest pediatric experience to date. It finds the devices to be life-saving, but also suggests that they tend to deliver more inappropriate shocks to children than to adults, making it important to watch children with ICDs closely.

The researchers, led by Charles Berul, MD, a cardiac electrophysiologist at Children’s Hospital Boston, analyzed data from 443 patients who received implants between 1992 and 2004 at one of four pediatric centers. The study included both pediatric heart patients and adults with congenital heart disease. The median age was 16 years (range, 0 to 54).

Among the 409 patients for whom shock data was available, 26 percent had received appropriate shocks from their ICD, averaging four per patient. However, 21 percent had received inappropriate shocks – an average of six per patient. When broken down by age, 24 percent of children under 18 had received inappropriate shocks, versus 14 percent of adult patients. While such shocks aren’t life-threatening, they are very unpleasant – “like being kicked in the chest,” says Berul.

One reason for the inappropriate shocks was that children often have spikes in heart rate that aren’t normally seen in adults. “Children are more active and get their heart rates up faster,” Berul says. “The devices sometimes have trouble differentiating normal increases in heart rate from abnormal rhythms.”

In addition, 14 percent of inappropriate shocks were due to failure of the ICD wires (leads). This was a particular problem in children, who live much longer with their ICDs than adults do, and whose leads can stretch due to activity and growth. Lead failure also requires periodic surgery to replace the wires.

Berul’s team is working with device manufacturers to change ICD programming to minimize unnecessary shocks in children and to provide more durable, longer-lasting leads. “Children are not an important market for device makers, but they are an important subgroup,” Berul says.

Overall, the study shows a benefit of ICDs, but suggests that physicians should give more attention to determining which children with congenital heart disease really need the devices, since not all are at risk for life-threatening arrhythmias. For example, patients who had experienced a prior cardiac event had a higher likelihood of appropriate shocks than those receiving the devices preventively (32 vs. 18 percent), improving the overall cost-benefit ratio.

Berul notes that the current study is by far the largest to date involving the newer generation of ICDs. It confirms the findings of earlier studies, which have looked at older-generation pacemakers and devices implanted only after children were resuscitated from cardiac arrest.

Source: Children's Hospital Boston

Explore further: West Africa's Ebola outbreak prompts changes in I.Coast cuisine

add to favorites email to friend print save as pdf

Related Stories

Hazy days: Berkeley lab tackles pollution in Mongolia

Jun 01, 2012

(Phys.org) -- Scientists at Lawrence Berkeley National Laboratory (Berkeley Lab) are known for designing high-efficiency cookstoves for Darfur and Ethiopia. Now they are applying their expertise to the windswept ...

Recommended for you

Two expats die of MERS in Saudi commercial hub

14 hours ago

Two foreigners died of MERS in the Saudi city of Jeddah, the health ministry said Saturday, as fears rise over the spreading respiratory virus in the kingdom's commercial hub.

UAE reports 12 new cases of MERS

14 hours ago

Health authorities in the United Arab Emirates have announced 12 new cases of infection by the MERS coronavirus, but insisted the patients would be cured within two weeks.

Filipino tests negative for Middle East virus

Apr 19, 2014

A Filipino nurse who tested positive for the Middle East virus has been found free of infection in a subsequent examination after he returned home, Philippine health officials said Saturday.

User comments : 0

More news stories

Less-schooled whites lose longevity, study finds

Barbara Gentry slowly shifts her heavy frame out of a chair and uses a walker to move the dozen feet to a chair not far from the pool table at the Buford Senior Center. Her hair is white and a cough sometimes interrupts her ...

Cancer stem cells linked to drug resistance

Most drugs used to treat lung, breast and pancreatic cancers also promote drug-resistance and ultimately spur tumor growth. Researchers at the University of California, San Diego School of Medicine have discovered ...

Making graphene in your kitchen

Graphene has been touted as a wonder material—the world's thinnest substance, but super-strong. Now scientists say it is so easy to make you could produce some in your kitchen.