Human tear fluids contain many proteins, metabolites, and other molecules whose concentrations change significantly with certain diseases. A research team has now developed a handy test kit for tears that can identify patients with jaundice. Their success is based on a hybrid sensor that simultaneously removes impurities from the sample. This approach could provide new methods for early detection and diagnosis based on complex bodily fluids, as the team reported in the journal Angewandte Chemie International Edition.

One particular advantage of tear fluid diagnosis is that samples can be collected in a comfortable and non-invasive manner. A method called surface-enhanced Raman spectroscopy (SERS) is a suitable candidate for the analysis of the biomolecules obtained. The Raman effect is a phenomenon in which light striking materials causes characteristic vibrations and rotations of molecular fragments. The resulting shift in the frequency of the scattered light gives a molecular "fingerprint."

If the analyte molecules are in contact with a (hotspots), the Raman signals are amplified enough to reach the ultra-sensitivity required for tear diagnostics. Labeling the analytes is unnecessary. Compact Raman hand devices would be available for direct diagnosis in the field. The problem is in finding suitable SERS sensors. Current sensors are quickly deactivated by deposition of tear components. Is there a way to make this work without complex sample preparation?

In fact, there is. A team led by Yun Feng (Peking University Third Hospital), Zhou Yang (University of Science and Technology Beijing), and Tie Wang (Tianjin University of Technology and Chinese Academy of Sciences Beijing), has demonstrated this with their novel matchbox-sized diagnostic test kit. At its heart lies a hybrid film. A layer of symmetrically arranged silicon dioxide nanospheres is coated with a whisper-thin layer of gold, onto which is deposited a layer of that act as SERS hotspots.

The target molecules bind to the gold and are held fast to the surface, while smaller tear components slip through the gaps between the silicon dioxide nanoparticles onto an absorbent layer below. The pore diameters can be adjusted by changing the size of the nanospheres to selectively separate out the disruptive primary components of tears (albumin, lysozyme, IgG, and peroxidase). The film, called SiO2@Au@AuNPs, is sandwiched between two glass supports and enclosed in a housing. A tip protrudes from the device to collect tear fluid from the corner of the eye. The SERS analysis occurs through a window on top of the device.

The team was able to successfully identify patients with jaundice—a metabolic disorder associated with liver and gall bladder diseases. The bile pigment bilirubin is not properly excreted from the body, becomes concentrated, and can be found in tear fluid. Bilirubin binds strongly to the sensor's gold and can be detected with great sensitivity by its SERS signal.

More information: Weidong Zhao et al, A Separation‐Sensing Platform Performing Accurate Diagnosis of Jaundice in Complex Biological Tear Fluids, Angewandte Chemie International Edition (2022). DOI: 10.1002/anie.202205628

Provided by Angewandte Chemie

Citation: Diagnosing jaundice using tear fluids (2022, June 23) retrieved 23 April 2024 from https://phys.org/news/2022-06-jaundice-fluids.html
This document is subject to copyright. Apart from any fair dealing for the purpose of private study or research, no part may be reproduced without the written permission. The content is provided for information purposes only.

Explore further

Scientists observe longitudinal plasmonic field in nanocavity at subnano-scale

48 shares

Feedback to editors