Laser tracks therapeutics, nutrients, toxins

May 16, 2017 by Anne M Stark
In biological systems, carbon-14 can be used as a biochemical tracer to track micro-doses of nutrients, toxins and therapeutics in humans and animals. Credit: Lawrence Livermore National Laboratory

Lawrence Livermore National Laboratory (LLNL) researchers have developed a laser-based tabletop device to measure carbon-14 (radiocarbon).

In biological systems, carbon-14 (14C ) can be used as a biochemical tracer to track micro-doses of nutrients, toxins and therapeutics in humans and animals. For example, the 14C can be tacked on to a vitamin. When a human ingests the vitamin, researchers can track how much of the vitamin metabolizes and how much is excreted through urine analysis.

For tracer studies in biochemical systems, 14C concentrations must be accurately measured at and above the natural abundance. In the past, this was typically done with (AMS). AMS opened new regimes of experimentation such as human phase drug trials using subtherapeutic doses. However, AMS' complexity and cost have limited this measurement method and other derivative techniques. Because of AMS' limitations, Livermore researchers developed a new device for biological tracer studies.

Cavity ring-down spectroscopy (CRDS) has emerged as a laser-based method capable of 14C measurements. Livermore scientists developed a CRDS spectrometer capable of measuring carbon-14 for biological studies. "We have developed a 14C spectrometer that balances complexity and sensitivity for biological 14C measurements," said Daniel McCartt, leader of the project. "It uses robust, mature hardware, suitable for a turnkey operation."

The Lab's Center for Mass Spectrometry (CAMS) partnered with Picarro Inc. The new laser-based system supplements the ion-source accelerator with a more accessible, tabletop device, which was patented last week.

Biological samples must be homogenized, dried and then combusted to for both AMS and CRDS. For traditional AMS, the carbon dioxide is then reduced to graphite. This requires approximately 12 hours. The CRDS system measures the 14C content of the combusted carbon dioxide, and a sample can be prepared in minutes.

For a pharmacokinetic case study, scientists used guinea pigs as the model organism and the carbon-14 content of samples was measured with CRDS and compared to AMS results. Guinea pigs were dosed with 100 mg of an oxime acetyltransferase reactivator, and tissue and plasma samples were taken in a geometric time series. The guinea-pig CRDS case study accurately reproduced the AMS results using relatively simple hardware, and zero day-to-day adjustments to the CRDS optical system.

Explore further: Ultra-sensitive, vibration-tolerant gas sensor makes field applications more practical

Related Stories

Biological sample prep time cut from days to minutes

October 15, 2014

When Lawrence Livermore National Laboratory researchers invented the field of biological accelerator mass spectrometry (AMS) in the late 1980s, the process of preparing the samples was time-consuming and cumbersome.

Recommended for you

Artificial photosynthesis gets big boost from new catalyst

November 20, 2017

A new catalyst created by U of T Engineering researchers brings them one step closer to artificial photosynthesis—a system that, just like plants, would use renewable energy to convert carbon dioxide (CO2) into stored chemical ...

Scientific advances can make it easier to recycle plastics

November 17, 2017

Most of the 150 million tons of plastics produced around the world every year end up in landfills, the oceans and elsewhere. Less than 9 percent of plastics are recycled in the United States, rising to about 30 percent in ...

0 comments

Please sign in to add a comment. Registration is free, and takes less than a minute. Read more

Click here to reset your password.
Sign in to get notified via email when new comments are made.