Study: Mechanomyography to be accurate in detecting nerves during minimally invasive spine surgery

Mar 15, 2010

An electronic device is an accurate technique for locating and avoiding nerves during spinal procedures, suggests a study by Henry Ford Hospital researchers.

The issue becomes important for patients as the demand for minimally invasive surgical techniques continues to grow, so does the need for effective methods for monitoring the location of nerves during surgery to avoid damage to them.

Mechanomyography (MMG) systems function by measuring the mechanical response of muscle following , compared to traditional techniques that monitor the electrical response of muscle using electromyography (EMG). EMG systems are widely used as intraoperative tools to help surgeons avoid injury. MMG has been widely used in laboratory settings to study things such as , however up until now it has not been applied as an intraoperative tool for locating nerves.

"We felt there was a safer and faster way to intra-operatively monitor the location of nerves and we wanted to test this theory by directly comparing MMG to EMG," says Stephen Bartol, MD, orthopedic spine surgeon at Henry Ford Hospital. "We found MMG to be extremely effective for detecting the presence of nerves during minimally invasive surgical procedures when the nerves could not be directly visualized."

Dr. Bartol presented results from the study this week at the Tenth Annual Scientific Conference of the Canadian Spine Society in Alberta.

According to the National Institutes of Health, in a three-month period, about one-fourth of U.S. adults experience at least one day of back pain. It is one of the most common medical issues affecting Americans.

During minimally invasive spine surgery, a common treatment for chronic back pain, a small is sometimes used to stimulate nerves and detect responses so that nerves are not damaged during surgery.

"Because conventional EMG systems monitor for subtle changes in muscle electrical activity, there is the potential for electrical interference. By using an MMG system, we are not worried about electrical interference since the response to electrical stimulation is measured through mechanical sensors instead," says Dr. Bartol.

In an animal model, Dr. Bartol and his colleagues measured the EMG and MMG responses to electrical current.

"We found that the MMG system had a faster response, indicating a higher sensitivity for detection of nerves at a lower threshold," says Dr. Bartol.

In another study, also presented at the conference, Dr. Bartol took a look at how the muscle response to electrical stimulus varies with the distance of the nerve from the source of the stimulus.

"We need to know exactly how far away we are from the nerve. Working with different levels of current, we were able to establish a relationship between the current and distance, allowing the surgeon to determine precisely how far a nerve is from the stimulus probe," says Dr. Bartol.

They found MMG detected the presence of a nerve on average 1.2 seconds earlier than EMG, using approximately half the amount of stimulating current. Since electrical resistance is highly variable, depending on the conducting tissue, EMG monitoring systems may utilize currents as high as 200 mA. The MMG system in this study has a maximum current output of 6 mA, nearly 35 times less than comparable EMG systems.

"We found mechanomyography to be a more sensitive indicator for locating nerves," says Dr. Bartol. "We can, without looking, know within a millimeter or two where we are in relation to the nerve. By utilizing a system that requires less electrical current, we may be able to further decrease the risk of injury to our patients."

Dr. Bartol explains that further investigation is needed in human trials.

Explore further: Do men's and women's hearts burn fuel differently?

add to favorites email to friend print save as pdf

Related Stories

Recommended for you

Do men's and women's hearts burn fuel differently?

2 hours ago

Researchers at the University of Illinois at Chicago College of Medicine will study gender differences in how the heart uses and stores fat—its main energy source—and how changes in fat metabolism play ...

Study suggests new source of kidneys for transplant

18 hours ago

Nearly 20 percent of kidneys that are recovered from deceased donors in the U.S. are refused for transplant due to factors ranging from scarring in small blood vessels of the kidney's filtering units to the organ going too ...

Do salamanders hold the solution to regeneration?

20 hours ago

Salamanders' immune systems are key to their remarkable ability to regrow limbs, and could also underpin their ability to regenerate spinal cords, brain tissue and even parts of their hearts, scientists have ...

Germ-fighting vaccine system makes great strides in delivery

23 hours ago

A novel vaccine study from South Dakota State University (SDSU) will headline the groundbreaking research that will be unveiled at the American Association of Pharmaceutical Scientists' (AAPS) National Biotechnology Conference ...

User comments : 0

More news stories

Study shows where scene context happens in our brain

In a remote fishing community in Venezuela, a lone fisherman sits on a cliff overlooking the southern Caribbean Sea. This man –– the lookout –– is responsible for directing his comrades on the water, ...

New rice contamination reported in China

Authorities are investigating rice mills in southern China following tests that found almost half of the staple grain in one of the country's largest cities was contaminated with a toxic metal.

NGOs denounce Malaysia hydropower meeting

Three dozen Malaysian NGOs on Tuesday denounced the world hydroelectric industry's decision to hold a conference in a Borneo state where dam projects have uprooted forests and native peoples.