Potential for noninvasive brain tumor treatment

Jun 16, 2009

Duke University engineers have taken a first step toward a minimally invasive treatment of brain tumors by combining chemotherapy with heat administered from the end of a catheter.

The proof-of-concept study demonstrated that it should be technically possible to treat brain tumors without the side effects associated with the traditional approaches of surgery, systemic chemotherapy or radiation.

The bioengineers designed and built an ultrasound catheter that can fit into large blood vessels of the brain and perform two essential functions: provide real-time moving 3-D images and generate localized temperature increases. The researchers envision using this system in conjunction with chemotherapy drugs encased in heat-sensitive microbubbles called liposomes.

"Physicians would inject drug-carrying liposomes into a patient's bloodstream, and then insert a catheter via a blood vessel to the site of the brain tumor," said Carl Herickhoff, fourth-year graduate student at Duke's Pratt School of Engineering and first author of a paper appearing in the journal Ultrasonic Imaging. "The catheter would use ultrasound to first image the tumor, and then direct a higher-power beam to generate heat at the site, melting the liposome shells and releasing the chemotherapy directly to the tumor.

"The temperature increase would be about four degrees Celsius - enough to melt the liposome, but not enough to damage surrounding tissue," Herickhoff said. "No one has tried this approach before in the brain."

The American Cancer Society estimates that more than 21,000 new brain tumor cases were diagnosed in 2008, with more than 13,000 patients dying. This represents about two percent of all cancer deaths.

The researchers said that a minimally invasive approach to treating this would be preferable to the conventional methods, which have drawbacks and side effects of their own.

"Surgery is invasive, and chemotherapy that is injected or taken orally affects the whole body and has difficulty crossing the blood-brain barrier in sufficient concentrations," Herickhoff said. The blood-brain barrier restricts the passage into the brain of any foreign matter not needed by the neural tissue.

In a series of experiments in animal models and simulated tissues, the researchers demonstrated that they could build a catheter thin enough to be placed in one of the brain's main blood vessels that was capable of serving the dual purpose of visualization and heating.

"Taken as a whole, the results of these experiments, in particular the clarity of the images and ability to increase temperature with the same catheter, lead us to believe that the ultimate creation of a practical intracranial ultrasound catheter is possible," said Stephen Smith, director of the Duke University Ultrasound Transducer Group and senior member of the research team. "There are some design issues of the catheter itself that we feel can be overcome with little difficulty."

Advances in ultrasound technology have made these latest experiments possible, the researchers said, by generating detailed, 3-D moving images in real-time. The Duke laboratory has a long track record of modifying traditional 2-D ultrasound - like that used to image babies in utero - into the more advanced 3-D scans. After inventing the technique in 1991, the team also has shown its utility in developing specialized catheters and endoscopes for real-time imaging of tissues throughout the body.

Much of the liposome research was carried out at Duke by David Needham, professor of mechanical engineering and materials science, and Mark Dewhirst, professor of radiation oncology.

Source: Duke University (news : web)

Explore further: Hospital volume not linked to costs of cancer surgery

add to favorites email to friend print save as pdf

Related Stories

Tiny 3-D ultrasound probe guides catheter procedures

Aug 28, 2008

An ultrasound probe small enough to ride along at the tip of a catheter can provide physicians with clearer real-time images of soft tissue without the risks associated with conventional x-ray catheter guidance.

First steps toward autonomous robot surgeries

May 06, 2008

The day may be getting a little closer when robots will perform surgery on patients in dangerous situations or in remote locations, such as on the battlefield or in space, with minimal human guidance.

New 3-D ultrasound could improve stroke diagnosis, care

Apr 24, 2008

Using 3-D ultrasound technology they designed, Duke University bioengineers can compensate for the thickness and unevenness of the skull to see in real-time the arteries within the brain that most often clog up and cause ...

New Brain Helmet Could Detect Stroke Earlier

Feb 09, 2009

(PhysOrg.com) -- A prototype "brain helmet" that provides real-time images of major blood vessels may enable emergency personnel to perform quick scans of potential stroke victims' brains, according to a team ...

Researchers Develop Breast Biopsy Robot

Feb 10, 2009

(PhysOrg.com) -- The results of proof-of-feasibility studies lead the researchers to believe that routine medical procedures such as breast biopsies will be performed in the future with minimal human guidance, and at greater ...

3-D ultrasound scanner provides in-depth view of the brain

Jun 20, 2007

Biomedical engineers at Duke's Pratt School of Engineering have adapted a three-dimensional ultrasound scanner that might guide minimally invasive brain surgeries and provide better detection of a brain tumor’s location.

Recommended for you

Hospital volume not linked to costs of cancer surgery

2 hours ago

(HealthDay)—Hospital surgical volume does not appear to correlate with Medicare payments for cancer surgery, according to research published online Nov. 24 in the Journal of Clinical Oncology.

How a common antacid could lead to cheaper anti-cancer drugs

4 hours ago

A popular indigestion medication can increase survival in colorectal cancer, according to research published in ecancermedicalscience. But in fact, scientists have studied this for years - and a group of cancer advocates want t ...

User comments : 1

Adjust slider to filter visible comments by rank

Display comments: newest first

E_L_Earnhardt
not rated yet Jun 16, 2009
COLD! - NOT HEAT! CYROABLATION IS ESTABLISHED AND EQUIPMENT IS AVAILABLE! YOU WANT TO SLOW ELECTRON SPEEDS, NOT ACCELERATE THEM!

Please sign in to add a comment. Registration is free, and takes less than a minute. Read more

Click here to reset your password.