Hybrid scanner brings molecular functioning to the forefront

Jun 15, 2009

A major barrier to developing a hybrid positron emission tomography (PET)/magnetic resonance (MR) imaging system could be removed by using a novel approach for reconstructing data, according to researchers at SNM's 56th Annual Meeting in Toronto. Many researchers view fused PET/MR as an important next step in improving imaging capabilities and believe that PET/MR could become a viable alternative to hybrid PET/computed tomography (CT) systems.

"Providing both PET and MRI capabilities in a single room could be a powerful tool for research and, eventually, for patient care," said André Salomon, Molecular Imaging Systems, Philips Research, Aachen, Germany. "Our successful approach to addressing a major shortcoming in data reconstruction could be an important breakthrough in the development of such a system."

A combined PET/MR system could deliver the specific molecular information related to cell surface reactors, enzymes and gene expression that PET provides. At the same time, physicians could use MRI to see important anatomical data, soft-tissue contrast and information about perfusion and permeability. However, a combined PET/MRI cannot provide accurate, reliable images unless it includes a method to account for PET attenuation. Attenuation refers to the scattering of photons that should be detected by PET scanners, but fall out of their range or are absorbed by the body instead.

In combined PET/CT systems, attenuation mapping is performed routinely based on available CT transmission data. Researchers are working on many alternatives to provide attenuation for PET/. Most of these involve methods of segmentation, atlas-based registration and computer learning techniques using databases with MR and corresponding CT images.

In this study, a novel new method for estimating attenuation uses a data reconstruction approach that simultaneously computes the activity and the attenuation distribution using the MR image as a geometrical reference. In this way, the true physical attenuation of the photons provided by the PET data is measured. Preliminary results from simulated and measured clinical data that were compared to reference data from CT attenuation maps indicate excellent agreement between the two techniques. In addition, performing time-of-flight reconstruction—which measures how long gamma rays produced by radionuclides reach PET detectors—also improves accuracy.

Source: Society of Nuclear Medicine

Explore further: Computational tool translates complex data into simplified 2-dimensional images

add to favorites email to friend print save as pdf

Related Stories

MRI/PET scanner combo

Mar 07, 2008

Two kinds of body imaging -- positron emission tomography (PET) and magnetic resonance imaging (MRI) -- have been combined for the first time in a single scanner.

PET outperforms CT in characterization of lung nodules

Feb 06, 2008

Researchers involved in a large, multi-institutional study comparing the accuracy of positron emission tomography (PET) and computed tomography (CT) in the characterization of lung nodules found that PET was far more reliable ...

Recommended for you

Preventing blood poisoning

May 17, 2013

Peptide molecules derived from the body's natural immune system can help boost the body's defence against life-threatening blood poisoning, joint University research has uncovered.

User comments : 0

More news stories

Heat-related deaths in Manhattan projected to rise

Residents of Manhattan will not just sweat harder from rising temperatures in the future, says a new study; many may die. Researchers say deaths linked to warming climate may rise some 20 percent by the 2020s, ...

Kinks and curves at the nanoscale

One of the basic principles of nanotechnology is that when you make things extremely small—one nanometer is about five atoms wide, 100,000 times smaller than the diameter of a human hair—they are going ...