Noninvasive screening test may detect narrowing in intracranial stents

Feb 11, 2009

Great advances have been made in treating blockages in the arteries of the brain using angioplasty to widen the narrowed artery and a stent to hold the artery open. However, in-stent stenosis, or a re-blockage of the artery within the stent due to scar tissue or blood clots, is estimated to occur in up to 30 percent of patients and can cause a stroke or death.

A new study by researchers at Rush University Medical Center has found that quantitative magnetic resonance angiography (QMRA) is a promising screening tool to detect in-stent stenosis with high sensitivity and specificity. The study is available early online and will appear in the March issue of Stroke: Journal of the American Heart Association.

Noninvasive imaging such as magnetic resonance angiography (MRA) and computerized tomography angiography often can not provide an accurate diagnosis of
in-stent stenosis because the image is distorted by the reflection of metal stents or coils. Due to this problem, conventional angiography continues to be used routinely after stent placement to screen for in-stent stenosis. However, conventional angiography requires threading a catheter from the arteries in the groin to the brain and carries a slight risk of neurological and non-neurological procedural complications.

Quantitative MRA (QMRA) is a flow analysis system that uses traditional MRI to produce a 3D model of the vasculature and quantify vessel blood flow. The procedure is completely non-invasive and no contrast is needed. Recent studies have established this technology's use in the measurement of arterial blood flow in various cerebrovascular conditions and carotid bypass surgery; however, this is the first study to assess the use of QMRA in the detection of intracranial in-stent stenosis.

The study authors conducted a retrospective review of 14 patients who underwent stent placement for cerebral aneurysm or intracranial stenosis. All patients had a QMRA scan performed within one year after stent placement and a follow-up diagnostic angiography study performed within one month of the QMRA scan. An interventional neurologist reviewed all angiograms for presence of greater than 50 percent in-stent stenosis.

The study found that low blood flow as measured by QMRA at sites of intracranial stent placement was significantly associated with in-stent stenosis by catheter-based angiography. As a screening tool to predict greater than 50 percent in-stent stenosis, QMRA was 100% sensitive. In other words, QMRA was able to detect narrowing of stented arteries in all cases where invasive angiography showed greater than 50 percent stenosis.

"Given the potentially deadly consequences of in-stent stenosis, a test with high sensitivity and an acceptably low false-positive rate is desirable," said Dr. Shyam Prabhakaran, section head of Cerebrovascular Disease and Neurological Critical Care at Rush. "In addition, none of the patients with normal QMRA results had stenosis on angiography, suggesting that patients with normal QMRA results may not require follow-up catheter-based angiography."

Due to the small sample size of the study, the authors suggest larger prospective studies to confirm their findings.

Source: Rush University Medical Center

Explore further: Liberia's Sirleaf sees signs of Ebola 'stabilisation'

add to favorites email to friend print save as pdf

Related Stories

Wireless sensor transmits tumor pressure

Sep 20, 2014

The interstitial pressure inside a tumor is often remarkably high compared to normal tissues and is thought to impede the delivery of chemotherapeutic agents as well as decrease the effectiveness of radiation ...

Eye implant could lead to better glaucoma treatment

Aug 26, 2014

For the 2.2 million Americans battling glaucoma, the main course of action for staving off blindness involves weekly visits to eye specialists, who monitor—and control—increasing pressure within the eye.

Tilted acoustic tweezers separate cells gently

Aug 25, 2014

Precise, gentle and efficient cell separation from a device the size of a cell phone may be possible thanks to tilt-angle standing surface acoustic waves, according to a team of engineers.

Designing exascale computers

Jul 23, 2014

"Imagine a heart surgeon operating to repair a blocked coronary artery. Someday soon, the surgeon might run a detailed computer simulation of blood flowing through the patient's arteries, showing how millions ...

Recommended for you

UN says Syria vaccine deaths was an NGO 'mistake'

11 hours ago

The recent deaths of Syrian children after receiving measles vaccinations was the result of a "mistake" by a non-governmental partner who mixed in a muscle relaxant meant for anesthesia, a spokesman for the U.N. secretary-general ...

First US child dies from enterovirus D68

11 hours ago

A child in the northeastern US state of Rhode Island has become the first to die from an ongoing outbreak of a respiratory virus, enterovirus D68, health officials said Wednesday.

US Ebola patient had contact with kids: governor

12 hours ago

A man who was diagnosed with Ebola in virus in Texas came in contact with young children, and experts are monitoring them for any signs of disease, governor Rick Perry said Wednesday.

UN worker dies of suspected Ebola in Liberia

12 hours ago

The United Nations mission in Liberia announced on Wednesday the first suspected victim among its employees of the deadly Ebola epidemic ravaging the impoverished west African nation.

User comments : 0