Study reveals embolic neuroprotection system reduces risk of cardiac events

Oct 16, 2008

Results of a study on the use of the FiberNet® Embolic Protection System in carotid artery stenting were reported today during the 20th annual Transcatheter Cardiovascular Therapeutics (TCT) scientific symposium, sponsored by the Cardiovascular Research Foundation (CRF). The research showed a low number of strokes and cardiac events in patients who had stents implanted utilizing a new embolic neuroprotection system during carotid stenting with commercial stents.

Subbarao Myla, MD, Medical Director CV Research and Vascular Intervention, Hoag Memorial Hospital, Newport Beach, Calif. presented the results of "EPIC: Evaluating the Use of the FiberNet® Embolic Protection System in Carotid Artery Stenting." The study looked at patients who were at high risk for CEA that were treated with the FiberNet® Embolic Protection System during carotid artery stenting procedures. The data was compiled into a registry that tracked 237 patients at 26 sites across the U.S.

The system uses a unique filter design with low porosity and, according to Dr. Myla, "Its easy-to-use features combined with aspiration prior to retrieval lead to low event rates. The FiberNet system allows blood flow during the procedure, a fiber-based filter captures particles as small as 40 µm and the stent is delivered for placement using a standard coronary guide wire."

In the study, patients at high-risk for CEA were treated in a prospective, multi-center, non-randomized trial. The demographic profile of study participants included patients of mean age 73.9± 8.3 (ranging from 46-89), 21.1% were octogenarians, 62.4% were male, 20.3% were symptomatic, 39.7% had diabetes and 22.2% were current smokers.

Key exclusion criteria included planned treatment of contra-lateral carotid within 30 days, stroke within 48 hours, myocardial infarction (MI) within 14 days, total occlusion, stenosis unsuitable for carotid stenting and serial lesions that require more than one stent.

The EPIC study revealed very low stroke, MI and death rates using the FiberNet embolic protection system during carotid stenting. Further, the low porosity filter and ease of use combined with aspiration prior to retrieval led to low event rates. The 30-day event rates showed deaths constituted 0.4% of all strokes 2.1% (major stroke ─ 1.3% and minor stroke ─ 0.9%) and all myocardial infarctions at 0.9%. The 30 day composite primary endpoint for all events was 3.0%

Procedural results included a 97.5% technical success rate, 94.1% FiberNet device success, 100% two-wall vessel apposition and 90.9% visible debris captured.

Source: Cardiovascular Research Foundation

Explore further: AbbVie to pay Shire $1.64B fee over nixed merger

add to favorites email to friend print save as pdf

Related Stories

Pharmaceuticals and the water-fish-osprey food web

7 hours ago

Ospreys do not carry significant amounts of human pharmaceutical chemicals, despite widespread occurrence of these chemicals in water, a recent U.S. Geological Survey (USGS) and Baylor University study finds. ...

Recommended for you

New MCAT shifts focus, will include humanities

7 hours ago

(HealthDay)—The Medical College Admission Test (MCAT) has been revised, and the latest changes, including more humanities such as social sciences, are due to be implemented next April, according to a report ...

Using feminist theory to understand male rape

18 hours ago

Decades of feminist research have framed rape and sexual assault as a 'women's issue', leaving little room for the experiences of male victims. But a new study published in the Journal of Gender Studies suggests that feminist ...

Simulation-based training improves endoscopy execution

Oct 18, 2014

(HealthDay)—Simulation-based training (SBT) improves clinicians' performance of gastrointestinal endoscopy in both test settings and clinical practice, according to research published in the October issue ...

User comments : 0