Exposing the Sensitivity of Extreme Ultraviolet Photoresists

Jun 26, 2008
Exposing the Sensitivity of Extreme Ultraviolet Photoresists
NIST researchers exposed a 300 mm silicon wafer with incrementally increasing doses of extreme ultraviolet light (EUV) in 15 areas. After the wafer was developed, the team determined that the seventh exposure was the minimum dose required (E0) to fully remove the resist. Credit: NIST

Researchers at the National Institute of Standards and Technology (NIST) have confirmed that the photoresists used in next-generation semiconductor manufacturing processes now under development are twice as sensitive as previously believed. This finding, announced at a workshop last month,* has attracted considerable interest because of its implications for future manufacturing. If the photoresists are twice as sensitive as previously thought, then they are close to having the sensitivity required for high volume manufacturing, but the flip side is that the extreme ultraviolet optical systems in the demonstration tools currently being used are only about half as effective as believed.

Extreme ultraviolet lithography (EUVL) is a process analogous to film photography. A silicon wafer is coated with photoresist and exposed to EUV light that reflects off a patterned “photomask.” Where the light strikes the resist it changes the solubility of the coating. When developed, the soluble portions wash away leaving the same pattern exposed on the silicon surface for the processing steps that ultimately create microcircuits.

The drive to make circuits with ever smaller features has pushed manufacturers to use shorter and shorter wavelengths of light. EUVL is the next step in this progression and requires developing both suitable light sources and photoresists that can retain the fine details of the circuit, balancing sensitivity, line edge roughness and spatial resolution. NIST researcher Steve Grantham says that optical lithography light sources in use today emit light with a wavelength of about 193 nanometers, which borders on optical wavelengths. EUVL sources produce light with wavelengths about an order of magnitude smaller, around 13.5 nanometers. Because this light does not travel through anything—including lenses—mirrors have to be used to focus it.

Until recently, EUV photoresist sensitivity was referenced to a measurement technique developed at Sandia National Labs in the 1990s. Late in 2007, scientists at the Advanced Light Source at Lawrence Berkeley National Laboratory in Berkeley, Calif., used a NIST-calibrated photodetector to check the standard. Their detector-based measurements indicated that the resist’s sensitivity was about twice that of the resist-based calibration standard.

Following on the intense interest that these results generated when the Berkeley group presented them at a conference in February, the Intel Corporation asked scientists at NIST to make their own independent determination of the EUVL resist sensitivity to validate the results. Measurements conducted at the NIST SURF III Synchrotron Ultraviolet Radiation Facility agreed with those of the Berkeley group. The fact that the photoresist is now known to be twice as sensitive to the EUV light implies that half as much light energy as had been expected is arriving at the wafer.

“These results are significant for a technology that faces many challenges before it is slated to become a high-volume manufacturing process in 2012,” Grantham says. “It should open the eyes of the industry to the need for accurate dose metrology and the use of traceable standards in their evaluations of source and lithography tool performance.”

Source: NIST

Explore further: Renesas announces SRAM using leading-edge 16 nm FinFET for automotive information systems

add to favorites email to friend print save as pdf

Related Stories

NIST 'combs' the atmosphere to measure greenhouse gases

Oct 29, 2014

By remotely "combing" the atmosphere with a custom laser-based instrument, researchers from the National Institute of Standards and Technology (NIST), in collaboration with researchers from the National Oceanic ...

New high-resolution X-ray spectrometer for beam lines

Oct 28, 2014

NIST scientists have pioneered a technology that may speed the arrival of long-awaited materials and devices including advanced high-temperature superconductors and high-efficiency photovoltaic cells: A new ...

New quantum probe enhances electric field measurements

Oct 07, 2014

Researchers at the National Institute of Standards and Technology (NIST) and the University of Michigan have demonstrated a technique based on the quantum properties of atoms that directly links measurements ...

Recommended for you

Electronic gadget for shaking hands over the Internet

4 hours ago

Takanori Miyoshi at the Department of Mechanical Engineering, Toyohashi University of Technology, has developed an innovative gadget that enables people to 'shake hands' over the Internet, irrespective of ...

User comments : 4

Adjust slider to filter visible comments by rank

Display comments: newest first

guiding_light
5 / 5 (2) Jun 27, 2008
What makes them think sensitivity is only based on the primary radiation? It is based on the process sensitivity to chemical effects from secondary electrons. This is strictly a random Monte Carlo number.
plasma_guy
5 / 5 (2) Jun 27, 2008
Mask defects are the big EUV killer.

http://www.semico...362.html
guiding_light
5 / 5 (2) Apr 26, 2009
I now think the variable number of secondary electrons generated in the photodiode for calculating wafer in-plane dose screwed them up.
guiding_light
not rated yet May 10, 2009
I now think the variable number of secondary electrons generated in the photodiode for calculating wafer in-plane dose screwed them up.


http://www.google...AAAAEBAJ&dq=patent:6710351&as_drrb_ap=q&as_minm_ap=0&as_miny_ap=&as_maxm_ap=0&as_maxy_ap=&as_drrb_is=q&as_minm_is=0&as_miny_is=&as_maxm_is=0&as_maxy_is=

Please sign in to add a comment. Registration is free, and takes less than a minute. Read more

Click here to reset your password.
Sign in to get notified via email when new comments are made.