How to measure individual platelets' strength

How to measure individual platelets' strength
PLatelets squeezing two protein dots together on top. Rows of protein dots in a deformable gel on lower left, the size of actual device on lower right. Credit: Wilbur Lam

Bleeding disorders could one day be diagnosed by putting platelets through strength tests, researchers have proposed.

Biomedical engineers from Emory and Georgia Tech have devised a microfluidic testing ground where platelets can demonstrate their strength by squeezing two protein dots together.

Imagine rows and rows of strength testing machines from a carnival, but very tiny. Platelets are capable of exerting forces that are several times larger, in relation to their size, in comparison with muscle cells.

After a blood clot forms, it contracts, promoting wound closure and restoration of normal blood flow. This process can be deficient in a variety of blood clotting disorders. Previously, it was difficult to measure individual platelet's contributions to contraction, because clots' various components got in the way.

The prototype diagnostic tools are described in Nature Materials.

"We discovered that platelets from some patients with bleeding disorders are 'wimpier' than platelets from healthy people," says Wilbur Lam, MD, PhD, assistant professor in the Department of Pediatrics at Emory University School of Medicine and in the Wallace H. Coulter Department of Biomedical Engineering at Georgia Tech and Emory University. "Our device may function as a new physics-based method to test for bleeding disorders, complementary to current methods."

The first author of the paper is instructor David Myers, PhD. Lam is also a physician in the Aflac Cancer and Blood Disorders Center, Children's Healthcare of Atlanta.

The scientists infer how strong or wimpy someone's are by measuring how far the protein dots move, taking a picture of the rows of dots, and then analyzing the picture on a computer. The dots are made of fibrinogen, a sticky protein that is the precursor for fibrin, which forms a mesh of insoluble strands in a blood clot.

In addition to detecting problems with platelet contraction in patients with known inherited disorders such as Wiskott Aldrich syndrome, Myers, Lam and colleagues could also see differences in some patients who had bleeding symptoms, but who performed normally on standard diagnostic tests.

The researchers also used chemical tools to dissect the process of platelet contraction. They showed that inhibitors of Rho/ROCK enzymes shut down platelet contraction, but inhibitors of a related pathway, MLCK (myosin light chain kinase), did not. Individual platelet contraction could become an assay for development or refinement of blood thinning drugs, Lam says.

More information: Single-platelet nanomechanics measured by high-throughput cytometry, Nature Materials, nature.com/articles/doi:10.1038/nmat4772

Journal information: Nature Materials

Provided by Emory University

Citation: How to measure individual platelets' strength (2016, October 10) retrieved 24 April 2024 from https://phys.org/news/2016-10-individual-platelets-strength.html
This document is subject to copyright. Apart from any fair dealing for the purpose of private study or research, no part may be reproduced without the written permission. The content is provided for information purposes only.

Explore further

Platelet biomechanics sheds light on coronary disease

11 shares

Feedback to editors