Low-power chip for intra-cardiac ventricular fibrillation detection

Feb 20, 2013
Imec’s low-power chip for intra-cardiac ventricular fibrillation detection.

Imec demonstrated a low-power (20µW), intra-cardiac signal processing chip for the detection of ventricular fibrillation at this week's International Solid State Circuits Conference (ISSCC 2013) in San Francisco with Olympus. An important step toward next-generation Cardiac Resynchronization Therapy solutions, the new chip delivers innovative signal processing functionalities and consumes only 20µW when all channels are active, enabling the miniaturization of implantable devices.

Robust and accurate Heart Rate (HR) monitoring of the right and left ventricles and right atrium is essential for for Cardiac Resynchronization Therapy. And accurate motion sensor and thoracic impedance measurements to analyze intra-thoracic fluid are critical for improving clinical research and analysis of the intra-. Moreover, extreme low-power consumption is required to further reduce the size of cardiac implants and improve the patient's quality of life.

Imec's low-power integrated circuit features three power-efficient, intra-cardiac signal readout channels (or in short: ECG channels). Each of the three ECG channels is equipped with a precision ECG signal readout circuit with very low-power consumption and an analog signal processor to extract the features of the ECG signal for detection of . The feature extractor achieves only 2ms latency to facilitate responsive Cardiac Resynchronization Therapy.

Additionally, the chip includes unique features that improve the functionality of devices. First, the low-power accelerometer readout channel enables rate adaptive pacing. Secondly, to handle intra-thoracic fluid analysis, the chip includes a 16-level digital sinusoidal current generator and provides 82db wide dynamic range bio-impedance measurement, in the range of 0.1Ω-4.4kΩ with 35mΩ resolution, and achieves best-in-class accuracy (>97%).

Explore further: New technology reduces size of spinal stimulator implants

add to favorites email to friend print save as pdf

Related Stories

Deaths reduced with cardiac resynchronization therapy

Jan 31, 2011

Cardiac resynchronization therapy shows major benefit in reducing mortality in people with heart failure when combined with optimal medical therapy or implantable cardioverter defibrillator, according to a study published ...

Imec unveils innovative technology for an ECG patch

Oct 11, 2011

Imec and Holst Centre announce an innovative body patch that integrates an ultra-low power electrocardiogram (ECG) chip and a Bluetooth Low Energy (BLE) radio. This unique combination fuses power-efficient ...

Wireless low-power active-electrode EEG headset presented

Oct 05, 2012

Imec, Holst Centre and Panasonic have developed a new prototype of a wireless EEG (electroencephalogram) headset. The system combines ease-of-use with ultra-low power electronics. Continuous impedance monitoring ...

Recommended for you

Senators get no clear answers on air bag safety

3 hours ago

There were apologies and long-winded explanations, but after nearly four hours of testimony about exploding Takata air bags, senators never got a clear answer to the question most people have: whether or ...

'Call of Duty' blasts past $10 bn in sales

4 hours ago

Blockbuster military shooter video game "Call of Duty" has blasted past $10 billion in lifetime sales, propelled by demand for the latest installment in the 11-year-old franchise.

User comments : 0

Please sign in to add a comment. Registration is free, and takes less than a minute. Read more

Click here to reset your password.
Sign in to get notified via email when new comments are made.