New method measures movements of tiny devices-at every step

Oct 17, 2012
A micromachine called a scratch drive actuator, labeled with fluorescent dots, (top) rests atop a platform underlain by an electric circuit that initiates the device?s step-by-step movements. Under a fluorescence microscope, the nanoparticles appear as points of light in a starlike constellation (bottom), making it possible to measure small changes in the position and orientation of the device at each step. Credit: NIST

(Phys.org)—Makers of minuscule moving machines—the kind being eyed for nanomanufacturing and assembly as well as other uses—do you know where your micro- and nanorobots really are?

Care to bet?

A team of researchers at the National Institute of Standards and Technology likely would likely prevail in such a hypothetical wager. On the basis of its surprising findings in an exacting study of the motions of an experimental (MEMS), the team might even offer better-then-even odds.

The group tracked, for the first time, the step-by-step motion of a standard type MEMS device called a "scratch drive actuator," a micromachine (120 micrometers wide, 50 micrometers long, and 1.5 micrometers thick) that drags itself over a surface by repeatedly flexing and relaxing a tiny hooked arm. Using a novel adapted from single molecule biophysics research, the researchers tracked and measured each of the device's 500 steps along a 20- path. They found that the incremental movements varied significantly, from just a few nanometers (nm) to almost 100 nm.

This marked variability in step sizes was "unexpected," says Craig McGray, the first author of the paper. Typically, MEMS researchers have calculated an average step size, derived from the total distance traveled by a device over many operating cycles. The resulting average does not show the variability of the step sizes, while simple models of the behavior of the device have conveyed the impression that the devices move in uniform increments.

Instead, McGray explains, "our method revealed very irregular step sizes, which had neither been observed previously nor predicted by established models of MEMS behavior."

In their experiment, the NIST team labeled the surface of a scratch drive actuator with fluorescent nanoparticles. Under a , the appeared as points of light in a starlike constellation. The position of each point of light was measured with exceedingly high accuracy, rendering the equivalent of a series of constellation maps and capturing the position and orientation of the device as it moved over a surface.

Before and after every step of the device along the path, two images of the constellation were taken. The data were then crunched to determine the step-by-step increments and rotations, and the uncertainty in both values.

With their innovative approach, the NIST team calculated both the size of each movement to within 1.85 nm, (smaller than the width of a strand of DNA) and the change in the device's orientation, also to an exceedingly low uncertainty. Rather than a straight line composed of evenly spaced points, the device took a somewhat ragged-edge route that curved slightly, with each step varying in length and orientation.

In a subsequent test, the researchers measured a second scratch drive actuator made by the same manufacturer. The results also differed unexpectedly and significantly, as indicated by a 26.3 nm difference in average step sizes.

Even as they work to refine their super-resolution fluorescence microscopy method, the team believes the approach can be broadly useful in the area of extremely small electromechanical systems.

Explore further: All directions are not created equal for nanoscale heat sources

More information: C.D. McGray, et al. MEMS kinematics by super-resolution fluorescence microscopy. Journal of Microelectromechanical Sytems. In press.

Related Stories

Three new standards for MEMS devices

Jul 16, 2004

Researchers at the National Institute of Standards and Technology (NIST), along with their colleagues at several companies, are completing experiments that validate new standards aimed at improving emerging new microelectromechanical ...

Measuring Electrical Arcs At the Micrometer Scale

Mar 30, 2006

Air is a great insulator—except when it becomes a conductor. Under the right conditions, miniature lightning bolts of electricity will “arc” through the air between two electrically conducting points. ...

NIST polishes method for creating tiny diamond machines

Sep 28, 2011

(PhysOrg.com) -- Diamonds may be best known as a symbol of long-lasting love. But semiconductor makers are also hoping they'll pan out as key components of long-lasting micromachines if a new method developed ...

Microtechnology: An alignment assignment

Jan 21, 2011

Microelectromechanical systems (MEMS), which consist of tiny moving parts driven by electrical signals, have found ready applications in optical communication systems. They are attractive in part because they ...

Recommended for you

New absorber will lead to better biosensors

10 hours ago

Biological sensors, or biosensors, are like technological canaries in the coalmine. By converting a biological response into an optical or electrical signal, they can alert us to dangers in our external and internal environments. ...

Ultrafast remote switching of light emission

Sep 30, 2014

Researchers from Eindhoven University of Technology can now for the first time remotely control a miniature light source at timescales of 200 trillionth of a second. They published the results on Sept. 2014 ...

Nanotube cathode beats large, pricey laser

Sep 30, 2014

Scientists are a step closer to building an intense electron beam source without a laser. Using the High-Brightness Electron Source Lab at DOE's Fermi National Accelerator Laboratory, a team led by scientist ...

User comments : 0