New circuit breakers prevent electrical fires

Oct 03, 2012
New circuit breakers prevent electrical fires
A new fire protection circuit breaker from Siemens prevents electrical fires from developing. The device registers dangerous arcing in an electrical installation and breaks the circuit automatically.

A new fire protection circuit breaker from Siemens prevents electrical fires from developing. The device registers dangerous arcing in an electrical installation and breaks the circuit automatically. Arcing can happen as a consequence of voltage flashovers in electrical circuits, for example, or occur due to a loose contact. In the past, some disturbances threw the breaker but others went unchecked. The new fire protection circuit breaker detects all kinds of arcing, effectively closing that gap. In the USA, arc fault circuit interrupters have been required by law since 2008. With the 5SM6 circuit breaker, Siemens is the first manufacturer to introduce this kind of device onto the European market.

Around a third of all fires in Germany are caused by - e.g. due to defective installation or an appliance fault. Installation defects often occur when wires are pinched or kinked, or has been damaged by a nail. If an arc flashes between two neighboring circuits, it causes them to short or ground out which will blow the fuse or trip the residual-current-operated circuit breaker. However, if an arc occurs within a circuit, for example across a break in a wire, it doesn't change the flow pattern of electricity and the defect goes unnoticed. In time, the point in the wire that is damaged will get so hot because of the arcing that it can catch fire.

New circuit breakers prevent electrical fires
As a complement to residual current operated circuit breakers and miniature circuit breakers, the Siemens 5SM6 AFD unit provides enhanced safety for people and assets and closes the gap in terms of protection against fires caused by electricity.

This is exactly where the circuit breaker comes in. It can detect all kinds of arcing by noting current and voltage characteristics. The difficulty is that there are situations where arcing is permissible and the circuit breaker shouldn't be tripped - for example, in electric drills and vacuum cleaners. A special evaluation software can identify dangerous arcing based on characteristic components in the current profile. When such a profile is observed, the circuit is broken within a fraction of a second and the arc is extinguished.

The fire protection circuit breaker has been designed to make retrofitting into older buildings no problem. The extra protection would be particularly suitable for bedrooms, especially if they have wooden walls, in buildings that require special protection such as orphanages and nursing homes, for machines that operate without being monitored (e.g. washing machines), and in buildings such as museums and libraries, where valuable objects are housed.

Explore further: Identifying long-distance threats: New 3D technology could improve CCTV images

add to favorites email to friend print save as pdf

Related Stories

Circuit-breaker detects all types of fault currents

May 11, 2005

The new universal-current-sensitive Type B residual-current circuit-breaker (r.c.c.b.) from Siemens Automation and Drives (A&D) can detect pulsating and smooth DC fault currents as well as sinusoidal AC fault currents. These ...

Cassini plasma spectrometer turns off

Jun 07, 2012

(Phys.org) -- The Cassini plasma spectrometer instrument (CAPS) aboard NASA's Cassini spacecraft was turned off between Friday, June 1 and Saturday, June 2, when a circuit breaker tripped off after the instrument ...

Magnetic ceramics films for smaller transformers

Oct 14, 2010

Siemens is developing magnetic ceramic films so that the high-performance electronic circuits used in lighting systems and other such devices can be made smaller and much easier to manufacture. This type of ...

Solar power coming to a store near you

Dec 10, 2009

(AP) -- Solar technology is going where it has never gone before: onto the shelves at retail stores where do-it-yourselfers can now plunk a panel into a shopping cart and bring it home to install.

Space station cooling system suddenly shuts down

Aug 01, 2010

(AP) -- Half of the International Space Station's cooling system suddenly shut down during the weekend, forcing the astronauts to power down equipment and face the likelihood of urgent spacewalking repairs.

Recommended for you

3D printed nose wins design award

13 hours ago

A Victoria University of Wellington design student is the New Zealand finalist for the James Dyson Award 2014 for his Master's project—a 3D printed prosthetic nose.

Engineering the Kelpies

14 hours ago

Recently, Falkirk in Scotland saw the opening of the Kelpies, two thirty metre high horse head sculptures either side of a lock in a new canal extension.

Technology on the catwalk

14 hours ago

Summer days bring thoughts of beach picnics, outdoor barbecues and pool parties. Yet it only takes the buzz of one tiny mosquito to dampen the fun.

Dismantling ships and the trajectory of steel

15 hours ago

Tell me how you dismantle a ship, and I'll tell how a region can prosper from its steel! This could be the motto of this master's cycle at ENAC during which the projects of two civil engineering students ...

User comments : 0