Smart gas sensors for better chemical detection

May 01, 2012

Portable gas sensors can allow you to search for explosives, diagnose medical conditions through a patient's breath, and decide whether it's safe to stay in a mine.

These devices do all this by identifying and measuring , and a new, more sensitive, smart model is under development at the University of Michigan. The could detect chemical weapon vapors or indicators of disease better than the current design. It also consumes less power, crucial for stretching battery life down a mineshaft or in isolated clinics.

In the gold standard method of gas detection, chemicals are separated before they are measured, said Xudong "Sherman" Fan, a professor in the Department of Biomedical Engineering.

"In a vapor mixture, it's very difficult to tell chemicals apart," he said.

The main advance of the sensor under development by Fan and his colleagues at U-M and the University of Missouri, Columbia, is a better approach to divvying up the chemicals. The researchers have demonstrated their concept on a table-top set-up, and they hope to produce a hand-held device in the future.

You can think of the different chemical vapors as tiny clouds, all overlapping in the original gas. In most today, researchers separate the chemicals into smaller clouds by sending the gas through two tubes in sequence. A on the inside of the first tube slows down heavier molecules, roughly separating the chemicals according to weight. The time it takes to get through the tube is the first clue to a chemical's identity, Fan explained.

A pump and compressor collect gas from the first tube and then send it into the second tube at regular intervals. The second tube is typically coated with polar polymers, which are positively charged at one end and negatively charged at the other. This coating slows down polar , allowing the non-polar molecules to pass through more quickly. With this second clue, the researchers can identify the chemicals in the gas.

The decision-maker added by Fan's group consists of a detector and computer that watch for the beginnings and ends of partially separated chemical clouds. Under its direction, the compressor only runs when there is a complete cloud to send through. In addition to consuming one-tenth to one-hundredth of the energy expended by the compressor in typical systems, this approach makes data analysis easier by keeping all molecules of one type together, said Jing Liu, a graduate student in Fan's group.

"It can save a lot of power, so our system can be used in remote areas," she said.

Because no gas can enter the second tube until the previous chunk has gone all the way through, the smart system takes up to twice as long to fully analyze the gas. However, adding alternative tubes for the second leg of the journey can get the system up to speed. Then, the decision-maker acts like a telephone operator.

"It can tell if one tube is 'busy' and send the gas to another line," Fan said.

This way, the device never stops the flow of the gas from the first tube. These second tubes can be customized for separating specific gasses, made to various lengths and with different coatings. As an example, Fan suggested that a dedicated tube for sensing specific molecules could serve as a "hotline."

"If we have suspicion that there are chemical weapon vapors, then we send that particular batch of molecules to this hotline," said Fan. "It could identify them with really high sensitivity."

Fan's team will study these sophisticated setups in the future. For now, they have proven that their decision-maker can distribute gas between two secondary tubes. Their smart sensors fully identified gasses containing up to 20 different chemicals, as well as compounds emitted by plants.

Explore further: A refined approach to proteins at low resolution

More information: Anal. Chem., 2012, 84 (9), pp 4214–4220 DOI: 10.1021/ac300588z

Related Stories

Breath or urine analysis may detect cancer, diabetes

Mar 10, 2009

(PhysOrg.com) -- A future sensor may take away a patient's breath while simultaneously determining whether the patient has breast cancer, lung cancer, diabetes or asthma. A University of Missouri researcher is developing ...

Digital quantum batteries inspired by plasma TVs

Jan 28, 2010

(PhysOrg.com) -- Plasma TVs are notorious for their excessive use of electricity, but the same principle used to produce high definition pictures in the TVs could result in the development of a new type of ...

New Device Shines Light on Disease-Causing Molecules

Jul 08, 2008

If a doctor could identify a single molecule indicating the presence of a disease before the disease has a chance to harm the patient, the practice of medicine and the health of patients would be greatly improved. That’s ...

3-D imaging to enable clean energy technologies

Mar 28, 2006

Ohio State University researchers have invented a technique to record three-dimensional scans of the gases and solids that mix inside boilers and other industrial processing reactors. Scientists can use the patented technique, ...

New gas sensor is tiny, quick

Jan 11, 2008

Engineers at MIT are developing a tiny sensor that could be used to detect minute quantities of hazardous gases, including toxic industrial chemicals and chemical warfare agents, much more quickly than current ...

Recommended for you

A refined approach to proteins at low resolution

4 hours ago

Membrane proteins and large protein complexes are notoriously difficult to study with X-ray crystallography, not least because they are often very difficult, if not impossible, to crystallize, but also because ...

Base-pairing protects DNA from UV damage

7 hours ago

Ludwig Maximilian University of Munich researchers have discovered a further function of the base-pairing that holds the two strands of the DNA double helix together: it plays a crucial role in protecting ...

Smartgels are thicker than water

7 hours ago

Transforming substances from liquids into gels plays an important role across many industries, including cosmetics, medicine, and energy. But the transformation process, called gelation, where manufacturers ...

Separation of para and ortho water

Sep 18, 2014

(Phys.org) —Not all water is equal—at least not at the molecular level. There are two versions of the water molecule, para and ortho water, in which the spin states of the hydrogen nuclei are different. ...