The quick and easy way to measure power consumption

May 10, 2012

The ambitious goals set by the German government to promote energy efficiency have put pressure on companies to change their energy-use policies. But the sustainable management of energy resources and the associated energy-saving measures can only be implemented if users have a reliable means of quantifying their power consumption. A novel sensor enables them to do just that, and thereby comply with the new government regulations. The new metering device will be presented at the Sensor+Test 2012 trade fair in Nuremberg from 22 to 24 May.

Until recently, large-scale industrial energy users in have benefited from reduced tax rates on the electricity and gas they consume. Now the has decided that companies will only be eligible for such tax breaks if they take steps to reduce their . From 2013 onward, will only be granted to companies equipped with an energy management system that provides details of their power consumption. This won’t be an easy task for the companies concerned, because it means they will have to install individual auxiliary meters to monitor the power consumption of individual loads such as presses and welding machines, or bakers’ ovens, or electric motors. And in many cases the metering instruments currently available on the market are too large to fit into existing power distribution cabinets. To remedy this situation, researchers at the Fraunhofer Institute for Integrated Circuits IIS in Erlangen have developed a novel, space-saving metering unit that can be simply clipped onto a power cable like a laundry peg, without even having to disconnect the load. The new “energy analyzer” was developed in collaboration with Rauschert GmbH – a manufacturer of advanced ceramic products that require energy-intensive production processes. The research project was funded by the Bavarian Ministry of Economic Affairs, Infrastructure, Transport and Technology as part of its microsystems technology program.

Using magnetic field sensors to measure power consumption

The device is based on the HallinOne 3-D magnetic field sensor originally developed by IIS for use in Bosch and Siemens branded washing machines, where it monitors the position and orientation of the rotating drum. “This new device is the first application in which we have used our 3-D magnetic-field sensor technology to measure the magnetic field generated by an electric current as a means of determining the energy consumed by the connected load. As such, it is an entirely novel approach,” says IIS research scientist Michael Hackner. To build the device, he and his team of qualified engineers mounted eight sensors, in the form of application-specific integrated circuits (ASICs), on a flexible, flat circuit board. What sets these sensors apart from more conventional designs is that they measure the magnetic field not only perpendicular to the surface of the chip but also in tangential directions, which improves measurement accuracy. The recorded data are transmitted to a microcontroller, which forwards them to a central processor via a gateway switch. “Our power sensor is quick to install and can be integrated online,” says Hackner, citing one of the advantages of the new product. He goes on to emphasize another unique design feature, namely the fact that it functions in the same way as a Rogowski coil, a component incorporated in many standard instruments used to measure electrical currents. “But the Rogowski coil only measures alternating current, whereas the IIS sensor can also measure direct current – an important consideration when measuring the power consumption of photovoltaic systems that include solar inverters for converting DC output into AC power.”

Highly accurate measurements

The metering device is cheap to build. And because the IIS researchers have not used any magetizable materials in its design, there are no accuracy errors from this source – a recurring problem with other clamp-on amp meters that cease to function correctly after a short-circuit. Another advantage is that, unlike clamp ammeters, the new device can also measure voltages. In short, users now have an all-in-one instrument capable of measuring all the parameters they need to monitor the quality of the grid supply in addition to the . Michael Müller, head of energy management systems at Rauschert GmbH, provides an example: “The new device helps us to rapidly identify production problems. We can immediately detect irregularities in the firing process and avoid having to scrap a whole batch of ceramics.” He intends to set up an energy-management consulting service for other plants in the group and equip them with the new measurement system.

Power sensor suitable for use in power utility networks

The sensor devices can even be installed in the power utility’s medium-voltage network (20 kV). As a result of the German Renewable Energy Sources Act (EEG), there are now a large number of small and medium-sized producers feeding energy into the grid, without being obliged (or able) to inform the energy provider exactly how much power is flowing on a specific line at any given time, and in what direction. “The grid capacity could be utilized much more efficiently if detailed measurement data were available,” affirm Hacker and Müller in unison. The two experts reckon there is huge market potential for this application: In Bavaria alone, the 20-kV distribution network contains tens of thousands of transformer stations, which could be equipped with the new, low-cost device without having to temporarily disconnect the stations or the transmission lines from the grid. A prototype measuring system for low-voltage networks has already been developed.

IIS researchers will present live demonstrations of the device at the Sensor+Test 2012 trade fair in Nuremberg from May 22 to 24 (Hall 12, Booth 202). The working prototype was built by Loewe Opta GmbH, who will also be manufacturing the final system.

Explore further: College students use 'smart' technology in football helmets to detect injuries

add to favorites email to friend print save as pdf

Related Stories

Magnetic Sensor That Brooks No Interference

Jun 03, 2008

Sensors accurately register the slightest temperature fluctuations, the tiniest changes to a magnetic field, or barely perceptible air currents. In some cases, however, there are limits to their accuracy – ...

Finding reserves on the electrical grid

May 11, 2011

The weather determines how much energy wind turbine systems provide. The same applies to power line capacity. On cold and stormy days, this capacity is higher than on days with no wind and high mid-summer ...

A power grid on a chip

Jun 09, 2011

Presented during the EPFL Middle East research days, a device only 4mm thick can manage an urban power grid a thousand times faster than currently possible.

Testing smart energy systems

Apr 05, 2011

A smartphone is all it takes to turn the heating on or off at home. This might sound like science fiction to the average user, but it is not unusual for the scientists at the Fraunhofer Institute for Solar ...

Analyzing energy potential

May 04, 2012

Sensors, radio transmitters and GPS modules all feature low power consumption. All it takes is a few milliwatts to run them. Energy from the environment - from sources such as light or vibrations - may be enough to meet these ...

Recommended for you

Building a machine that sorts candy colors with iPhone

Dec 23, 2014

The very idea of a machine being able to color-sort M&Ms teases an inventor's imagination and interest in machines, electronics and programming. A person with a website called "reviewmylife" had heard about ...

Laser technology aids CO2 storage capabilities

Dec 23, 2014

DOE's National Energy Technology Laboratory is attracting private industry attention and winning innovation awards for harnessing the power of lasers to monitor the safe and permanent underground storage ...

FAA, industry launch drone safety campaign

Dec 22, 2014

Alarmed by increasing encounters between small drones and manned aircraft, drone industry officials said Monday they are teaming up with the government and model aircraft hobbyists to launch a safety campaign.

User comments : 0

Please sign in to add a comment. Registration is free, and takes less than a minute. Read more

Click here to reset your password.
Sign in to get notified via email when new comments are made.