New microscope captures nanoscale structures in dazzling 3D

Apr 19, 2012 By Justin Eure and Peter Genzer
Collaborators from Photon Sciences and Sustainable Energy Technologies stand behind the new transmission x-ray microscope (TXM) at Brookhaven’s National Synchrotron Light Source. From left: Yu-chen Karen Chen-Wiegart, Can Erdonmez, Jun Wang (team leader), and Christopher Eng.

(Phys.org) -- A new x-ray microscope probes the inner intricacies of materials smaller than human cells and creates unparalleled high-resolution 3D images. By integrating unique automatic calibrations, scientists at the U.S. Department of Energy’s Brookhaven National Laboratory are able to capture and combine thousands of images with greater speed and precision than any other microscope. The direct observation of structures spanning 25 nanometers will offer fundamental advances in many fields, including energy research, environmental sciences, biology, and national defense.

This innovative full field transmission x-ray microscope (TXM), funded by the American Reinvestment and Recovery Act, was developed and commissioned at Brookhaven Lab’s National Synchrotron Light Source (NSLS), which provides the x-ray source needed to capture images on the nanoscale. A new paper published in the April 2012 Applied Physics Letters details the experimental success of a breakthrough system that rapidly combines 2D images taken from every angle to form digital 3D constructs.

“We can actually see the internal 3D structure of materials at the nanoscale,” said Brookhaven physicist Jun Wang, lead author of the paper and head of the team that first proposed this TXM. “The device works beautifully, and it overcomes several major obstacles for x-ray microscopes. We’re excited to see the way this technology will push research.”

Building an extra dimension

Wang’s team examined, for example, a 20-micrometer electrode from a lithium-ion battery – as thin around as a human hair. The internal interaction of pores and particles determines the energy performance of the battery, and examining that activity requires precise knowledge of the nanoscale structure.

Wang’s team took 1,441 2D pictures of the electrode as a machine rotated the tiny material specimen to capture every possible angle. The challenge then becomes converting those separate images into a single 3D structure – one in which every nanometer makes a difference. On this scale, the usual one-micron wobbles are similar in scale to taking a portrait and having the subject leap several feet to either side.

This 3D reconstruction of a lithium-ion battery electrode, composed of 1,441 individual images captured and aligned by the TXM, reveals nano-scale structural details to help guide future energy research.

Before this new system, scientists had to manually align every single image or use software to slowly interpret the shifts. This had two major limiting effects on the process: first, the sample has to have sharp internal features or be marked to provide guidelines, which can limit material types; and second, manual alignment demands so much time that the total image count peaks in the hundreds. Brookhaven’s TXM changes that.

For the first time, the specimen is mounted on top of a platform with three sensors that measure nanometer shifts in any direction as the battery rotates and the microscope takes pictures. The computer recording the images, after calibration using a gold sphere, then automatically compensates for any shifts and accurately assembles the into the final three-dimensional construct. The entire process takes only four hours, and that owes more to the x-rays available from NSLS than the microscope or computer.

The future of 3D

Brookhaven’s National Synchrotron Light Source II (NSLS-II), scheduled to come online in 2015, will exploit the capabilities of this TXM on an even more radical scale. Imaging that lithium-ion battery took 10,000 seconds on NSLS, but with the new light source’s higher beam flux, or x-ray brightness, it will be 1,000 times faster, dropping that time to only 10 seconds.

In addition to direct structural observation, the TXM will also advance elemental and chemical understanding of materials. Maintaining constant magnification during spectroscopic imaging, which examines the unique ways that matter interacts with radiation, scientists will be able to identify the individual chemical configurations within samples. Research is currently under way by Wang’s team to demonstrate this capability.

Nanoimaging for industry and national security

The TXM was purchased with support from the American Recovery and Reinvestment Act, designed to spur economic activity and create jobs. Xradia, a California-based company that specializes in 3D x-ray microscopy, built the new device. Brookhaven Lab physicists worked in close collaboration with Xradia engineers, explaining their specific research goals and performance needs.

“This has been a very successful collaboration, and Xradia has been our critical partner in this project,” said Wang. “We are still in frequent contact to provide them with feedback on the microscope’s performance, so that future design innovations can be made.”

While the focus for the new TXM will likely be on alternative energy fuels and storage solutions, the fundamental insights have already been applied to plant root structures, catalysts, and advanced electronics. The demonstrated success of the 3D imaging system has already attracted the interest of commercial users, with major corporations such as UOP and IBM scheduling time at the TXM. The Defense Advanced Research Projects Agency (DARPA) also plans to use the new to probe the intricate structures of imported microchips in the interest of national security.

Explore further: Engineers discover new method to determine surface properties at the nanoscale

Related Stories

Better batteries through nanoscale 3D chemical imaging

Aug 09, 2011

Concerns over the finite availability of oil and the effect of greenhouse gases on climate have spurred intense efforts to develop electric-drive vehicles; the major barrier to successful commercialization ...

Brookhaven lab's new light source halfway there

Mar 22, 2011

(PhysOrg.com) -- The U.S. Department of Energy’s Brookhaven National Laboratory is now halfway toward completing construction of the National Synchrotron Light Source II (NSLS-II), a powerful x-ray microscope ...

Coherent diffractive imaging in living color

Aug 11, 2011

(PhysOrg.com) -- Exactly 150 years after the first color photograph was produced, scientists have devised a way of employing the full spectrum of colors from synchrotron and free-electron laser x radiation ...

Recommended for you

New 2-D quantum materials for nanoelectronics

Nov 21, 2014

Researchers at MIT say they have carried out a theoretical analysis showing that a family of two-dimensional materials exhibits exotic quantum properties that may enable a new type of nanoscale electronics.

Thin film produces new chemistry in 'nanoreactor'

Nov 19, 2014

Physicists of the University of Groningen and the FOM Foundation, led by professor Beatriz Noheda, have discovered a new manganese compound that is produced by tension in the crystal structure of terbium manganese oxide. ...

User comments : 5

Adjust slider to filter visible comments by rank

Display comments: newest first

krajczinski
not rated yet Apr 19, 2012
Excited to see how this will be implemented in medical imaging
antialias_physorg
5 / 5 (1) Apr 19, 2012
It's not going to come to medical imaging. The radiation levels needed for that kind of resolution are way too high. Sure, you'd get good pics, but you'd fry the patient in the process.
jibbles
5 / 5 (1) Apr 20, 2012
"The Defense Advanced Research Projects Agency (DARPA) also plans to use the new microscope to probe the intricate structures of imported microchips in the interest of national security."

imported microchips? hmm
Terriva
not rated yet Apr 20, 2012
The research team doesn't appear like typical Americans as well...
antialias_physorg
5 / 5 (1) Apr 20, 2012
imported microchips?

It's just an euphemism for reverse engineering and industrial espionage. All nations and all major companies X-ray the products of theircompetitors.

For DARPA it's an additional safeguard against nasties added to the microchips made in China.

Please sign in to add a comment. Registration is free, and takes less than a minute. Read more

Click here to reset your password.
Sign in to get notified via email when new comments are made.