Common for patients to undergo multiple cardiac imaging tests, with high cumulative radiation dose

Nov 15, 2010

Multiple testing with the cardiac diagnostic imaging technique of myocardial perfusion imaging is common, and in many patients is associated with a high cumulative estimated radiation dose, according to a study in the November 17 issue of JAMA. The study is being released early online because it is being presented at the American Heart Association's annual meeting.

Use of has grown rapidly in recent years, but along with the potential benefits has come an increase in the amount of ionizing radiation associated with many such tests and the accompanying potential risks of cancer. "Although much attention has been paid to radiation from computed tomography (CT) scans, a recent study demonstrated that the single test with the highest radiation burden, accounting for 22 percent of cumulative effective dose from medical sources, is myocardial perfusion imaging (MPI). Volume of MPI increased from less than 3 million procedures in the United States in 1990 to 9.3 million in 2002, and it is now estimated to account for more than 10 percent of the entire cumulative effective dose to the U.S. population from all sources, excluding radiotherapy," according to background information in the article. Few data are available to characterize the total radiation burden received over an extended period by patients undergoing MPI.

Andrew J. Einstein, M.D., Ph.D., of Columbia University Medical Center and New York-Presbyterian Hospital, New York, and colleagues analyzed procedures involving ionizing radiation received by a group of patients who received MPI to evaluate the total numbers of MPI examinations, other tests involving radiation, cumulative effective doses of radiation, and clinical indications for testing and repeat testing. The study included 1,097 patients undergoing MPI during the first 100 days of 2006 (January 1-April 10) at Columbia University Medical Center. The researchers evaluated all preceding medical imaging procedures involving undergone beginning October 1988, and all subsequent procedures through June 2008, at the center.

Patients underwent a median (midpoint) of 15 procedures involving radiation exposure, of which 4 were high-dose procedures, defined as an effective dose of at least 3 mSv (millisievert; a measure of ), the equivalent of 1 year's natural background radiation. A total of 200 patients (18.2 percent) had at least 3 MPIs and 4.9 percent had at least 5 MPI examinations.

The researchers found that the median cumulative estimated effective dose from MPI alone was 28.9 mSv, and for all medical testing, was 64.0 mSv. A total of 71 patients (6.5 percent) received cumulative doses of more than 100 mSv due to MPI alone, and 31.4 percent of patients received more than 100 mSv from all medical sources, including 120 patients (10.9 percent) who received cumulative dose of more than 200 mSv.

The primary reason for testing was chest pain, breathing difficulty, or both in 66.8 percent of examinations. More than 80 percent of initial and 90 percent of repeat MPI examinations were performed in patients with known cardiac disease or symptoms consistent with it. Of 1,097 patients undergoing index MPI, 38.6 percent underwent additional MPI studies. For this group of patients undergoing multiple MPIs, the median cumulative estimated effective dose was 121 mSv.

Patients undergoing multiple MPI examinations were significantly more likely to be older and male. Men and white patients had higher cumulative estimated effective doses.

"Our study reveals very high cumulative estimated effective doses to many patients undergoing MPI, and especially to patients undergoing repeat MPI testing. More than 30 percent of patients received a cumulative estimated effective dose of more than 100 mSv, a level at which there is little controversy over the potential for increased cancer risks," the authors write. "Efforts are needed to decrease this high cumulative dose and its potential attendant risks."

They add that "although the high cumulative doses observed are certainly a matter of concern and an important target for improvement, these doses should not be viewed in isolation but rather within the clinical context where radiation risk for a specific patient is balanced against potential benefits."

Explore further: Chronic inflammation linked to 'high-grade' prostate cancer

More information: JAMA. 2010;304[19]:2137-2144

add to favorites email to friend print save as pdf

Related Stories

Recommended for you

Unraveling the 'black ribbon' around lung cancer

Apr 17, 2014

It's not uncommon these days to find a colored ribbon representing a disease. A pink ribbon is well known to signify breast cancer. But what color ribbon does one think of with lung cancer?

User comments : 0

More news stories

Filipino tests negative for Middle East virus

A Filipino nurse who tested positive for the Middle East virus has been found free of infection in a subsequent examination after he returned home, Philippine health officials said Saturday.

Study says we're over the hill at 24

(Medical Xpress)—It's a hard pill to swallow, but if you're over 24 years of age you've already reached your peak in terms of your cognitive motor performance, according to a new Simon Fraser University study.

NASA's space station Robonaut finally getting legs

Robonaut, the first out-of-this-world humanoid, is finally getting its space legs. For three years, Robonaut has had to manage from the waist up. This new pair of legs means the experimental robot—now stuck ...

Ex-Apple chief plans mobile phone for India

Former Apple chief executive John Sculley, whose marketing skills helped bring the personal computer to desktops worldwide, says he plans to launch a mobile phone in India to exploit its still largely untapped ...

Egypt archaeologists find ancient writer's tomb

Egypt's minister of antiquities says a team of Spanish archaeologists has discovered two tombs in the southern part of the country, one of them belonging to a writer and containing a trove of artifacts including reed pens ...

Airbnb rental site raises $450 mn

Online lodging listings website Airbnb inked a $450 million funding deal with investors led by TPG, a source close to the matter said Friday.