New stent design demonstrates superiority at 6 months; 1 year data to be presented at TCT 2010

Sep 21, 2010

A new drug-eluting stent design demonstrated superiority over a traditional drug-eluting stent at 6 months, according to a study led by Laura Mauri, MD, Associate Professor of Medicine, Brigham and Women's Hospital, Harvard Medical School (Boston, MA.) The study is being presented at the 22nd annual Transcatheter Cardiovascular Therapeutics (TCT) scientific symposium, sponsored by the Cardiovascular Research Foundation.

"This new stent proved superior to a traditional drug-eluting stent for the primary endpoint of in-stent late loss at 6 months. This was associated with a trend for better clinical outcomes and an absence of stent thrombosis. The bioresorbable polymer and stent design are targeted to mitigate thrombosis risk without compromising anti-restenotic efficacy," said Dr. Mauri.

Traditional drug eluting stents (DES) deliver an anti-proliferative drug to the vessel wall from a durable polymer which homogeneously covers the outer surface of the stent. The stent used in this study is a sirolimus-eluting coronary stent system that combines a bioresorbable PLGA polymer with the antiproliferative agent sirolimus within a novel reservoir technology on a chromium-cobalt stent platform, reducing spatial and temporal polymer exposure. After drug and polymer reabsorption, all that remains is an inert metallic stent.

Eligible patients had single de-novo lesions ≤28mm in native coronary arteries 2.5 - 3.5mm. The primary endpoint was in-stent late loss (LL) at 6 months. Secondary endpoints included death, myocardial infarction (MI), clinically driven target lesion (TLR) and target vessel revascularization (TVR) and the composite endpoints MACE (death, MI, TLR), target lesion failure (cardiac death, target vessel-related MI, TLR), and ARC adjudicated stent thrombosis (ST). IVUS was performed in a subgroup of 100 patients. Clinical follow-up is to be completed at 1, 6, and 12 months and annually to 5 years. Angiographic follow-up was performed at 6 months.

A total of 394 patients were enrolled at 40 sites in 9 countries from March to October 2008. The primary endpoint, in-stent LL at 6 months, (0.13±0.31mm for NEVO™ and 0.36±0.48mm for TAXUS® Liberté) reached statistical significance for the non-inferiority and superiority hypothesis (P < 0.001). superiority was also demonstrated for the pre-defined subgroups of diabetes, stent diameter, and lesion length < or > 20mm. While not powered for clinical endpoints, 6 month outcomes showed lower event rates for the NEVO™ group: death (0.5% vs. 1.6%, P=0.36); MI (2.0% vs. 2.6%, P=0.75); TLR (1.5% vs. 3.7%, P=0.21); MACE (4.0% vs. 7.9%, P=0.13.) No stent was observed for NEVO™, while 2 cases occurred in the TAXUS group. IVUS showed lower neointimal volume for NEVO™ (5.8±11.7mm3 vs 19.5±24.7mm3, P=0.004).

12-month outcome data will be presented be during the Drug-Eluting and Bare Metal Stent Studies I Oral Abstract Session on Wednesday, September 22 in Room 140A at the Washington Convention Center.

Explore further: A high-fat diet may alleviate mitochondrial disease

Related Stories

Study examines use of stent with bioabsorbable polymer

Sep 21, 2010

Three-year data demonstrated that satisfactory clinical and safety outcomes of sirolimus eluting stents with a biodegradable polymer were sustained in a real world setting. The results were presented at the 22nd annual Transcatheter ...

Recommended for you

A high-fat diet may alleviate mitochondrial disease

18 hours ago

Mice that have a genetic version of mitochondrial disease can easily be mistaken for much older animals by the time they are nine months old: they have thinning grey hair, osteoporosis, poor hearing, infertility, ...

Cheek muscles hold up better than leg muscles in space

18 hours ago

It is well known that muscles need resistance (gravity) to maintain optimal health, and when they do not have this resistance, they deteriorate. A new report published in the July 2015 issue of The FASEB Journal, however, sugges ...

Sialic acid: A key to unlocking brain disorders

21 hours ago

A new report published in the July 2015 issue of The FASEB Journal suggests that a common molecule found in higher animals, including humans, affects brain structure. This molecule may play a significant role in how brain ...

User comments : 0

Please sign in to add a comment. Registration is free, and takes less than a minute. Read more

Click here to reset your password.
Sign in to get notified via email when new comments are made.