Few complications one year after aortic valve implantation

September 21, 2009

Research presented at the 21st annual Transcatheter Cardiovascular Therapeutics (TCT) scientific symposium, sponsored by the Cardiovascular Research Foundation (CRF), demonstrated an "exceptionally low" rate of complications one year after implantation of transcatheter aortic valve prostheses.

The aortic valve study was led by Sabine Bleiziffer, MD, consultant , German Heart Center Munich, Munich, Germany, and will be presented as a poster abstract (TCT-111) on Tuesday, September 22 between 8:00 a.m. and 10:00 a.m. in Hall D of The Moscone Center.

"Transcatheter aortic valve implantation with the self-expandable prosthesis is an effective and durable treatment for patients with aortic stenosis not eligible for surgical aortic valve replacement," said Dr. Bleiziffer.

Between June 2007 and April 2009, 179 prostheses were implanted in non-surgical candidates via a number of different routes: transfemoral (164 patients), transapical (5 patients), subclavian artery (7 patients), and ascending aorta (3 patients). Patients were a mean age of 81 ± 7y, with a mean STS score of 19 ± 11% and symptomatic high-grade aortic stenosis (mean valve orifice area 0.7 ± 0.2cm², mean aortic gradient 48 ± 18 mm Hg).

Periprocedural complications included femoral access site complications in 13% of the patients, dialysis for postoperative renal failure in 8%, neurologic events in 7%, and permanent pacemaker implantation in 26%. 30 day-, 6 months-, and 1 year-survival was 88%, 78%, and 78%, respectively.

Freedom from bleeding events, thromboembolic events, structural valve deterioration and prosthestic endocarditis was 83%, 97%, 99% and 97% at one year. Non-structural valve deterioration or valve thrombosis did not occur. Mean aortic gradient decreased to 11 ± 4 mm Hg (valve size 26) and 12 ± 4 mm Hg (valve size 29), and valve orifice area increased to 1.4 ± 0.4cm² (valve size 26) and 1.5 ± 0.3cm² without change up to one-year follow-up.

The study concluded that multiple vascular access sites are feasible for implantation of the prosthesis because of the small diameter of the delivery sheath. Periprocedural complications are considerable but related to the high risk patient population. Mid-term valve-related complications are exceptionally low and the gradient release after prosthesis implantation is stable up to one year of follow-up.

"A close and careful follow-up of patients treated with the new technology of transcatheter valve implantation including history of valve-related complications and echocardiographic assessment is crucial to approve the quality of the technique and to redefine indications for future patients," said Dr. Bleiziffer.

Source: Cardiovascular Research Foundation

Explore further: Major discovery in the treatment of aortic valve stenosis

Related Stories

Major discovery in the treatment of aortic valve stenosis

April 18, 2008

A team of scientists from the Université de Montréal and the Montreal Heart Institute Research Centre, led by Dr. Jean-Claude Tardif, has completed an important study that show how a new type of medication can lead to an ...

'Healthy' sterols may pose health risk

July 14, 2008

Plant sterols have been touted as an effective way to lower cholesterol and reduce the risk of heart disease. However, a research study in the July JLR has uncovered that these compounds do have their own risks, as they can ...

Heart valves implanted without open-heart surgery

January 7, 2009

An innovative approach for implanting a new aortic heart valve without open-heart surgery is being offered to patients at NewYork-Presbyterian Hospital/Columbia University Medical Center. Known as the PARTNER (Placement of ...

Diseased heart valve replaced through small chest incision

February 10, 2009

When 91-year-old Irvin Lafferty was diagnosed with severe blockage of his heart valve—hardening that is formally known as aortic valve stenosis—open-heart surgery was out of the question. He'd already survived quadruple ...

Recommended for you

Machine Translates Thoughts into Speech in Real Time

December 21, 2009

(PhysOrg.com) -- By implanting an electrode into the brain of a person with locked-in syndrome, scientists have demonstrated how to wirelessly transmit neural signals to a speech synthesizer. The "thought-to-speech" process ...

Quantum Theory May Explain Wishful Thinking

April 14, 2009

(PhysOrg.com) -- Humans don’t always make the most rational decisions. As studies have shown, even when logic and reasoning point in one direction, sometimes we chose the opposite route, motivated by personal bias or simply ...

0 comments

Please sign in to add a comment. Registration is free, and takes less than a minute. Read more

Click here to reset your password.
Sign in to get notified via email when new comments are made.